Convenient functions
−28−
8.4 Items displayed on the driver
Operation mode: Monitor mode
Item
Display
Description
Rotation speed
*
0
•
Monitors the rotation speed of the motor.
•
Monitors the rotation speed of the gear output shaft or conveyor transfer speed
when the "speed reduction ratio" parameter is set.
•
When the "speed increasing ratio" parameter is set, the rotation speed being
increased by the external mechanism is displayed.
Load factor
t -
The motor generating torque can be checked. The present load factor is displayed
based on the rated torque being 100%. The load factor is displayed in 1%
increment between 40% and 200%, and "
t -
" is displayed if the load factor is
smaller than 40%.
The display is the load factor on the motor output shaft. It is not for the gearhead
output shaft.
With the combination type product, the permissible torque varies depending on the
gear ratio of the gearhead.
Use the product so that the load does not exceed the permissible torque of the
gearhead output shaft.
When the slight position-keeping is enabled, "
t H
" is displayed.
Operation data No.
opE0
Monitors the operation data No. currently selected.
Alarm
AL00
When an alarm generates, the alarm code is displayed. You can also reset alarms
or check and clear alarm records. Refer to p.33 for alarm type.
Warning
_wn00
When a warning generates, the warning code is displayed. You can also check
and clear warning records. Refer to p.35 for warning type.
I/O monitor
o
You can check the ON/OFF status of each I/O signal of the driver. If the signal is
ON, the corresponding digit is lit. If the signal is OFF, the digit is unlit.
IN0
IN1
IN2
OUT0
OUT1
Input
signals
Output
signals
IN4
IN3
*
For the factory setting, the rotation speed is displayed when the power is turned on.
The display for when turning on the power can be changed using the parameter. "Panel initial view" parameter: p.26
Display of the rotation speed
•
Displayed digit number when setting the speed reduction ratio or speed increasing ratio
Since the number of significant figures for the integer part is changed if the speed reduction ratio or speed increasing ratio is set,
the digit number displayed on the panel will also be changed.
Setting value for the speed reduction
ratio and speed increasing ratio
Display on the
monitor mode
1.00 to 9.99
0 to 9999
10.00 to 99.99
0.0 to 999.9
100.0 to 999.9
0.00 to 99.99
1000 or more
0.000 to 9.999
Содержание BMU5200A Series