background image

Convenient functions

−24−

8.2  Setting items and panel displays

M

M

M

M

M

M

M

M

M

M

M

M

M

M

F

F

F

F

F

M

F

F

F

F

F

F

F

F

F

M

F

M

F

M

F

M

F

M

M

M

M

M

F

F

F

M

M

M

M

M

F

M

F

M

F

M

F

M

2

2

2

Speed setting
(blinking display)

Monitor mode

Top screen

Load factor

Operation data No.

Alarm

Warning

Alarm record 1

Return to the "alarm record 1"

Clear alarm
record 

1

Warning record 1

Clear warning
record 

1

Alarm 
reset

Return to the "warning record 1"

I/O monitor

Return to the

"rotation speed"

Return to the "input monitor"

Input monitor

Output monitor

Data mode

Return to the "rotation speed 0"

Return to the 

"operation 

data No.0"

Operation
data No.0

Rotation
speed 0
 

Acceleration
time 0

Deceleration
time 0

Data setting

Data setting

Data setting

Initialize
data 0

Execution

Return to the "rotation speed 3"

Rotation
speed 3

Acceleration
time 3

Deceleration
time 3

Data setting

Data setting

Data setting

Initialize
data 3

Execution

Operation
data No.3
        

Rotation
speed

Return to the "monitor mode"

Returns to
the display at
power ON
(Only if an alarm
is present)

Power ON

The display for when turning on the power can be changed using the "panel initial view" parameter.

1

1

Содержание BMU5200A Series

Страница 1: ...400 W OPERATING MANUAL Thank you for purchasing an Oriental Motor product This Operating Manual describes product handling procedures and safety precautions Please read it thoroughly to ensure safe op...

Страница 2: ...2 8 Convenient functions 23 8 1 Functions list 23 8 2 Setting items and panel displays 24 8 3 Parameter list 26 8 4 Items displayed on the driver 28 8 5 Setting the operation data 29 8 6 Setting the a...

Страница 3: ...ng the operation without removing the cause of the problem may result in malfunction of the motor and driver leading to injury or damage to equipment Installation The motor and driver are Class I equi...

Страница 4: ...ay result Securely install the load on the motor gearhead output shaft Inappropriate installation may result in injury Connection Be sure to ground the product to prevent it from being damaged by stat...

Страница 5: ...on when using under low temperature environment When an ambient temperature is low since the load torque may increase by the oil seal or viscosity increment of grease used in the gearhead the output t...

Страница 6: ...flat Degree of protection of the motor P IP65 blank IP40 Power supply input A Single phase 100 120 V C Single phase Three phase 200 240 V S Three phase 200 240 V Output power 200 200 W 400 400 W Moto...

Страница 7: ...he operation switch to the RUN side causes the motor to start running Setting the operation switch to the STAND BY side causes the motor to stop This switch is used to change the motor rotation direct...

Страница 8: ...plets or chemicals This motor can be used in an environment that is splashed with water excluding the connector part and the mounting surface of the round shaft type Not available for use under high p...

Страница 9: ...sections of the motor and gearhead Also assemble the motor and gearhead carefully by not pinching the O ring at the motor pilot section If the O ring is crushed or severed grease may leak from the ge...

Страница 10: ...on parts Gearhead model Screw size Effective depth GFV6G M6 12 mm 0 47 in Permissible radial load and permissible axial load The radial load and the axial load on the output shaft of the motor gearhea...

Страница 11: ...r exceeds the upper limit of the operating ambient temperature revise the ventilation condition or force cool the area around the driver using a fan Installation method Install the driver to a flat me...

Страница 12: ...ted L1 L2 and L3 only Connector model FKC2 5 3 ST 5 08 LR PHOENIX CONTACT GmbH Co KG Connecting the lead wire Connect to insert the lead wire to the connector Applicable lead wire AWG18 to 14 0 75 to...

Страница 13: ...nit mm in Driver Two Protective Earth Terminals PE are provided on the driver Ground either of the two Protective Earth Terminals near the driver You can ground either of the two Protective Earth Term...

Страница 14: ...er supply 24 VDC 15 to 20 100 mA or more Output signal circuit The driver outputs signals are photocoupler open collector output The ON voltage of the output circuit is max 1 5 V When driving each ele...

Страница 15: ...round Motor connection Motor ground NC Motor connector CN1 CN2 N L PE Motor Main circuit Control circuit Driver CN4 4 7 IN COM1 0 V 5 0 V N Circuit breaker Shielded cable Functional grounding 820 IN1...

Страница 16: ...e case of 5 VDC 150 to 560 0 5 W Source logic 24 VDC CN4 4 5 to 30 VDC 100 mA or less 100 mA or less 0 V 5 6 4 3 2 1 6 6 k 6 6 k 6 6 k 6 6 k 6 6 k 820 820 820 820 820 12 R R 10 11 9 Programmable contr...

Страница 17: ...the input voltage 200 W type 400 W type Note When cycling the power or plugging unplugging the connector turn off the power and wait for 1 minute or more before doing so Ensure that the connector plug...

Страница 18: ...et data is saved in the operation data No 0 Refer to p 24 for details Confirmation If the setting dial is pressed while the motor stops the set speed is displayed blinking several times Operating with...

Страница 19: ...d relays Operation This operation example is for when the rotation speed is set to the operation data No 0 Setting the External operation signal input parameter The external operation signal input par...

Страница 20: ...ayed The data mode parameter mode and the I O monitor of the monitor mode are enabled possible to set The display time of rE varies depending on the switch When setting the operation switch to the RUN...

Страница 21: ...the motor by selecting any of the operation data No 0 to No 3 based on a combination of ON OFF status of the M0 and M1 inputs The motor is operated using the rotation speed acceleration time and dece...

Страница 22: ...ise CCW CW If the rotation direction switch is changed the motor will decelerate to a stop and start rotating in the direction being switched If the external operation signal input parameter is set to...

Страница 23: ...nal is output Setting Rotation speed Sets the motor rotation speed using the setting dial 18 Sets the motor rotation speed in the operation data 29 Acceleration time deceleration time Sets using the a...

Страница 24: ...ed Return to the input monitor Input monitor Output monitor Data mode Return to the rotation speed 0 Return to the operation data No 0 Operation data No 0 Rotation speed 0 Acceleration time 0 Decelera...

Страница 25: ...ing Data setting Data setting Data setting Speed upper limit Data setting Speed lower limit Data setting Data setting Data setting Signal selection 0 Signal selection 0 Data setting Signal selection 4...

Страница 26: ...ArSt Resets using the ALARMRESET input or the alarm reset on the monitor mode Analog acceleration deceleration time tAtD Changes the setting method of acceleration deceleration time An Sets using the...

Страница 27: ...I O signals Signal Terminal Signal name Description Input IN0 IN1 IN2 IN3 IN4 FWD The motor rotates when either of the FWD input or REV input is turned ON If the FWD input and REV input are turned ON...

Страница 28: ...eration data No currently selected Alarm AL00 When an alarm generates the alarm code is displayed You can also reset alarms or check and clear alarm records Refer to p 33 for alarm type Warning _ wn00...

Страница 29: ...d as follows 20 4 1300 63 7 Conveyor transfer speed m min Accordingly 20 4 is shown on the panel Display while an alarm generates The alarm code is displayed while the alarm generates and the screen c...

Страница 30: ...min from the standstill state Deceleration time The deceleration time is set as the time needed for the motor to stop from the rated rotation speed 3000 r min Acceleration time Deceleration time r min...

Страница 31: ...is setting range can be changed to limit Setting range of the rotation speed r min r min Example When limiting the speed range by setting to the speed upper limit to 3000 r min and the speed lower lim...

Страница 32: ...ameter Up to 50 of the rated torque is generated according to the angle variation of the motor output shaft figure The position of a load exceeding 50 of the rated torque cannot be kept When the power...

Страница 33: ...driver and motor AL30 Overload A load exceeding the continuous duty region was applied to the motor for the time exceeded the value set in the overload alarm detection time except when holding a shaf...

Страница 34: ...the operation signal is the FWD input ALARM OUT1 output ON OFF ALARM RESET input ON OFF FWD input Motor operation ON OFF 10 ms or more 10 ms or more CW CW Stop Reset with the monitor mode Set the oper...

Страница 35: ...w the ambient temperature Review the ventilation condition in the enclosure _ wn30 Overload A load exceeding the overload warning level parameter was applied to the motor Check the load condition _ wn...

Страница 36: ...eed The motor rotates in the direction opposite to the specified direction The FWD input and REV input are connected wrongly or otherwise not connected correctly Check the connection of the FWD input...

Страница 37: ...uct The driver uses semiconductor elements so be extremely careful when handling them Electrostatic discharge can damage the driver During inspection Are any of the motor gearhead mounting screws loos...

Страница 38: ...ignments of the motor cable that comes out of the motor The following figure is as view from the direction of the motor lead wires side Motor connector White Pin No Color Lead eire 6 5 4 3 2 1 Housing...

Страница 39: ...the signal cables CN4 by means of double insulation Applicable Standards Motor EN 60034 1 EN 60034 5 EN 60664 1 Driver EN 61800 5 1 Installation conditions EN Standard Motor Driver For incorporating...

Страница 40: ...provides in the power line in order to prevent the noise generated within the driver from propagating outside via the AC input line For mains filters use the products as shown in the chart or an equiv...

Страница 41: ...y providing a minimum clearance of 100 mm 3 94 in between them If they must cross do so at a right angle Place the AC input cable and output cable of a mains filter separately from each other Use a co...

Страница 42: ...freezing Ambient Humidity 85 or less non condensing Altitude Up to 1000 m 3300 ft above sea level Surrounding atmosphere No corrosive gas or dust Cannot be used in radioactive materials magnetic fiel...

Страница 43: ...43...

Страница 44: ...nowledged The third party products mentioned in this manual are recommended products and references to their names shall not be construed as any form of performance guarantee Oriental Motor is not lia...

Отзывы: