8
•
Unauthorized reproduction or copying of all or part of this manual is prohibited.
•
Oriental Motor shall not be liable whatsoever for any problems relating to industrial
property rights arising from use of any information, circuit, equipment or device
provided or referenced in this manual.
•
Characteristics, specifications and dimensions are subject to change without notice.
•
While we make every effort to offer accurate information in the manual, we welcome
your input. Should you find unclear descriptions, errors or omissions, please contact the
nearest office.
•
is a registered trademark or trademark of Oriental Motor Co., Ltd.,
in Japan and other countries.
© Copyright ORIENTAL MOTOR CO., LTD. 2020
Published in March 2020
Technical Support Tel:(800)468-3982
8:30
A.M.
to 5:00
P.M.
, P.S.T. (M-F)
7:30
A.M.
to 5:00
P.M.
, C.S.T. (M-F)
www.orientalmotor.com
Schiessstraße 44, 40549 Düsseldorf, Germany
Technical Support Tel:00 800/22 55 66 22
www.orientalmotor.de
Tel:01256-347090
www.oriental-motor.co.uk
Tel:01 47 86 97 50
www.orientalmotor.fr
Tel:02-93906346
www.orientalmotor.it
Tel:+55-11-3266-6018
www.orientalmotor.com.br
• Please contact your nearest Oriental Motor office for further information.
4-8-1Higashiueno,Taito-ku,Tokyo 110-8536
Japan
Tel:03-6744-0361
www.orientalmotor.co.jp
Tel:0800-060708
www.orientalmotor.com.tw
Singapore
Tel:1800-8420280
www.orientalmotor.com.sg
Tel:1800-806161
www.orientalmotor.com.my
Korea
Tel:080-777-2042
www.inaom.co.kr
Tel:1800-888-881
www.orientalmotor.co.th
Tel:400-820-6516
www.orientalmotor.com.cn
Tel:+91-80-41125586
www.orientalmotor.co.in
Hong Kong Branch
Tel:+852-2427-9800
Inspection and maintenance
Inspection
It is recommended that periodic inspections would be conducted for the items listed
below after each operation of the motor. If an abnormal condition is noted, discontinue
any use and contact your nearest Oriental Motor sales office.
Note
•
Do not conduct the insulation resistance measurement or dielectric
strength test with the motor and driver connected. Doing so may cause
damage to the product.
•
Do not conduct the insulation resistance measurement or dielectric
strength test on an encoder Doing so may damage the encoder.
z
Inspection item
•
Check if any of the mounting screws of the motor and gearhead is loose.
•
Check if the bearing part (ball bearings) of the motor generates unusual noises.
•
Check if the bearing part (ball bearings) or gear meshing part of the gearhead generates
unusual noises.
•
Check if the output shaft of the motor and gearhead and a load shaft are out of
alignment.
•
Check if a damage or stress is applied on the cable or the connection part between the
cable and driver is loose.
Warranty
Check on the Oriental Motor Website for the product warranty.
Disposal
Dispose the product correctly in accordance with laws and regulations, or instructions of
local governments.
Specifications
Check on the Oriental Motor Website for the product specifications.
General specifications
Operating
environment
Ambient
temperature
0 to +50 °C [+32 to +122 °F] (non-freezing)
Ambient
humidity
85% or less (non-condensing)
Altitude
Up to 1000 m (3300 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust.
Cannot be used in radioactive materials, magnetic field,
vacuum or other special environment
(For details about installation locations, refer to p.4.)
Vibration
Not subject to continuous vibrations or excessive impact.
In conformance with JIS C 60068-2-6 "Sine-wave vibration
test method"
Frequency range: 10 to 55 Hz
Pulsating amplitude: 0.15 mm
Sweep direction: 3 directions (X, Y, Z)
Number of sweeps: 20 times
Storage
environment
Shipping
environment
Ambient
temperature
−20 to +60 °C [−4 to +140 °F] (non-freezing)
Ambient
humidity
85% or less (non-condensing)
Altitude
Up to 3000 m (10000 ft.) above sea level
Surrounding
atmosphere
No corrosive gas, dust, water or oil.
Cannot be used in radioactive materials, magnetic field,
vacuum or other special environment.
Degree of protection
IP54 (Excluding the mounting surface of the round shaft
type and the connector part)
Regulations and standards
UL Standards, CSA Standards
This product is recognized by UL under the UL and CSA Standards.
The motor model name represents the model that conforms to the standards.
Output power
Applicable Standards
Certification body
Standards File No.
30 W
60 W
120 W
UL 60950-1
CSA C22.2 No.60950-1
UL
E208200
200 W
400 W
UL 1004-1
CSA C22.2 No.100
E335369
*
Thermal class UL/CSA Standards: 105 (A)
CE Marking
This product is affixed the CE Marking under the Low Voltage Directive.
The motor model name represents the model that is affixed CE Marking.
z
Low Voltage Directive
•
This product is designed and manufactured to be incorporated in equipment.
•
This product cannot be used in IT power distribution systems.
•
Install the product inside an enclosure in order to avoid contact with hands.
•
When installing the motor and driver, securely connect their Protective Earth Terminals.
•
Isolate the motor cable, power supply cable and other drive cables from the encoder
cable and signal cables (CN5 to CN7) by means of double insulation.
z
Applicable standards
Motor: EN 60034-1, EN 60034-5, EN 60664-1
Installation conditions (EN Standards)
•
To be incorporated in equipment.
•
Overvoltage category:
Ⅲ
•
Pollution degree: 3
•
Protection against electric shock: Class
Ⅰ
*
Thermal class EN Standards: 120 (E)
RoHS Directive
The products do not contain the substances exceeding the restriction values of RoHS
Directive (2011/65/EU).