11
Copyright Orenco Systems
®
, Inc. Property of Orenco Systems
®
, Inc. Do not reproduce or distribute without written authorization from Orenco: 800-348-9843. •
AIM-OM-ATX-3, Rev. 2.1, 05/15
AdvanTex
®
O
&
M
MANUAL
C O M M E R C I A L T R E A T M E N T S Y S T E M S
e. Measure and compare the dynamic (running) voltage of the pumps
to the measured static (resting) voltage. Voltage drops indicate
connection problems in the splice box or wiring that is too small for
the pump.
f. Use an ammeter to measure the pump amperage. Make sure
the amperage is within the range specified in the table below or
listed on the pump nameplate. For non-Orenco pumps, consult the
manufacturer’s literature.
NOTE:
On TCOM panels with a current sensor option, pump
amperage should match the value listed in the panel. If it does not
match, inspect the three-position switch on the current sensor for
the correct scaling factor.
g. Set the high and low amperage ranges based on the reading.
Inspection Points (continued)
Pump Amperage Chart
Pump Model
Low Amp
Reading
High Amp
Reading
Pump Model
Low Amp
Reading
High Amp
Reading
PF100511
11.9
12.6
PF30503200
15.4
18.6
PF100512
6.0
6.4
PF500511
10.5
12.1
PF10053200
3.5
3.9
PF500512
5.4
6.2
PF100552
3.6
3.8
PF500532
2.6
3.0
PF100712
7.8
8.4
PF50053200
3.2
3.7
PF10073200
4.9
5.2
PF500534
1.3
1.5
PF100752
5.8
6.2
PF500552
3.3
3.9
PF101012
9.0
9.8
PF500712
7.3
8.5
PF10103200
5.1
5.6
PF500732
3.1
3.9
PF101552
9.4
11.4
PF50073200
3.9
4.9
PF102012
10.0
12.2
PF500734
1.4
1.8
PF102032
6.4
7.6
PF501012
8.8
10.1
PF10203200
7.5
8.7
PF50103200
4.6
5.7
PF200511
11.0
12.5
PF501034
1.8
2.2
PF200512
5.8
6.5
PF501512
9.6
12.6
PF200532
2.5
2.9
PF50153200
5.4
7.0
PF20053200
3.3
3.8
PF501552
8.0
9.1
PF201012
9.6
10.5
PF503012
12.6
17.7
PF300511
10.7
11.8
PF503032
8
10.4
PF20103200
5.0
5.9
PF50303200
10.1
13.1
PF20153200
6.0
7.2
PF503034
4.2
5.3
PF201512
10.5
12.6
PF505012
17.3
26.4
PF300512
5.6
6.2
PF505032
13.1
16.5
PF30053200
3.3
3.7
PF751512
11.4
12.3
PF300552
3.5
4.2
PF300712
7.4
8.6
P200511
12.6
13.8
PF300752
5.5
6.1
P200512
6.1
7.1
PF30073200
4.1
4.9
P201512
11.2
12.2
PF301012
9.3
10.4
P300512
5.8
6.5
PF301052
6.4
7.4
P300712
7.4
8.3
PF30103200
4.9
5.8
P301012
9.1
10.3
PF301512
10.1
12.6
P500511
11.2
12.7
PF30153200
5.5
6.9
P500512
5.8
6.5
PF301534
2.3
2.8
P50053200
3.4
3.8
PF301552
8.1
9.3
P500712
7.7
8.8
PF302012
7.4
11.0
P50073200
3.8
4.8
PF30203200
7.7
9.3
P501012
9.4
11.2
PF303012
12.6
16.8
P501512
10.6
13.1
PF303032
8.2
10.1
P50153200
6.0
7.6
PF305012
20.1
25.8
PF305032
14.0
16.6
PEF3311
6.9
7.8