background image

7

EN

16

4

5

6

4.  Insert wind sensor into the top of the bracket.
5.  Using screws, fix aluminium pole firmly into place.
6.  Slide outdoor sensor onto bracket.

  IMPORTANT   

For  best  results,  point  the  wind  vane 

North.

ALTERNATIVE SET UP:  TEMPERATURE / 

HUMIDITY SENSOR MOUNTED SEPARATELY

1.  Insert 4 type A screws into the holes of the sensor 

connector.  Screw firmly into place, i.e., fence.

SET UP RAIN GAUGE

The rain gauge collects rain and takes readings of rainfall 
rate and the total rainfall over a period of time. The sensor 
can remotely transmit data to the base station.

The base station and rain gauge should be positioned 
within an effective range: about 100 meters (328 feet) 
in an open area.

The rain gauge should be mounted horizontally about 1 
meter (3 feet) from the ground in an open area away from 
trees or other obstructions to allow rain to fall naturally 
for an accurate reading.

To set up the Rain Gauge:

1.  Remove screws and slide the cover off in an upwards 

motion. 

2.  Insert  the  batteries  (2  x  UM-3  /  AA),  matching  the 

polarities  (+  /  -).    Press 

RESET

  after  each  battery 

change.

3.  Remove the fibre tape.

To ensure a level plane:

Put a few drops of water on the cross at the base of the 
funnel to check the horizontal level.

1

2

3

4

Water will pool to the center of the cross when the rain 
gauge is level.

If water remains on 1-4, the gauge is not horizontal.

If necessary, adjust the level using the screw.

 NOTE 

 For best results, ensure the base is horizontal to 

allow maximum drainage of any collected rain.

Содержание WMR100N

Страница 1: ...ainfall 12 Weather Alarms 12 Set Up Software First time use 12 Additional step for Windows Vista users only 12 Install software 13 Disable Sleep Mode 13 To disable sleep mode on computer 13 Windows XP...

Страница 2: ...ity or UV readings in various locations Optional wireless remote sensors such as those listed below can be purchased separately For more information please contact your local retailer Solar Panel STC8...

Страница 3: ...a 1 2 3 4 5 6 7 8 9 1 Temperature trend 2 Wind Chill level temperature is showing 3 Heat Index level temperature is showing 4 HI LO temperature HI Heat Index and LO Wind Chill alarms are set 5 Selecte...

Страница 4: ...1 Clock radio reception 2 Alarm 1 and 2 are displayed and set 3 Timestamp is displayed 4 Offset time zone 5 Moon phase 6 Time date calendar Humidity Dew Point Area 1 2 3 4 5 6 1 Dew point level Temper...

Страница 5: ...anemometer from the wind sensor carefully 2 Insert batteries matching the polarities and replace the anemometer Press RESET after each battery change 3 3 Slide wind vane onto the end of the plastic at...

Страница 6: ...ment bracket on top of the top pole 11 Using two screws x it rmly into place To mount the temperature humidity sensor 12 12 Slide outdoor sensor onto vertical attachment bracket To mount the wind sens...

Страница 7: ...00 meters 328 feet in an open area The rain gauge should be mounted horizontally about 1 meter 3 feet from the ground in an open area away from trees or other obstructions to allow rain to fall natura...

Страница 8: ...hange the display and settings use the following buttons on the rotating dial SELECT MEMORY ON OFF MODE and ALARM In addition the UNIT and SEARCH buttons located at the bottom of the base station allo...

Страница 9: ...2 is displayed Alarm 1 or 2 is activated No icons No alarm is set To set an alarm 1 Press SELECT to navigate to the Clock Area will show next to the Area 2 Press ALARM to toggle between alarm 1 and a...

Страница 10: ...Index MAX Wind Chill 1 only MIN Humidity Humidity Indoor and 1 10 outdoor MAX MIN Dew Point MAX MIN The timestamp is displayed accordingly in the Clock Area To clear the memories and timestamp for the...

Страница 11: ...te or deactivate the alarm UVI BAROMETER RAINFALL The weather station works with one UV sensor and one rain gauge The station is capable of storing and displaying the hourly history data for the last...

Страница 12: ...l reading display Press and hold MEMORY ON OFF to reset the accumulated rainfall to 0 and to set the timestamp to current date and time To change the HI rainfall rate alarm 1 In the UV Barometer Rainf...

Страница 13: ...1 Right click on Desktop 2 In context menu click on Properties 3 Click on Screen Saver tab in the Display Properties dialogue box 4 Click on Power located at the bottom half of dialogue box 5 In new d...

Страница 14: ...level User setting for compensation Weather display Sunny Partly Cloudy Cloudy Rainy and Snowy Memory Historical data and bar chart for last 24hrs INDOOR TEMPERATURE Temp unit C F Displayed range 0 C...

Страница 15: ...this product ensure it is collected separately for special treatment and not as household waste Placement of this product on certain types of wood may result in damage to its nish for which Oregon Sci...

Страница 16: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Отзывы: