Operating range

-30°C to 60°C (-4°F to 140°F)

Accuracy

-20°C – 0°C: +/- 2°C (+/- 4.0°F)
0°C - 40°C: +/- 1°C (+/- 2.0°F)
40°C - 50°C: +/- 2°C (+/- 4.0°F)
50°C - 60°C: +/- 3°C (+/- 6.0°F)

Comfort

20°C to 25°C (68°F to 77°F)

Memory

Current, Min and Max temp.
Dew Point w/ Max and Min
Wind chill temp. and min

• 

RELATIVE HUMIDITY

Displayed range

2% to 98%

Operating range

25% to 90%

Resolution

1%

Accuracy

25% - 40%: +/- 7%
40% - 80%: +/- 5%
80% - 90%: +/- 7%

Comfort

40% to 70%

Memory

Current, Min and Max

Battery 

2 x UM-4 (AAA) 1.5V batteries

RF TRANSMISSION

RF frequency

433MHz

Range

Up to 100 meters (328 feet) with
no obstructions

Transmission

Approx. every 60 seconds

No. of Channel

1 for Wind/ Rain/ UV and 10 for
Temp. / Humidity

REMOTE RAIN GAUGE

Dimensions

114 x 114 x 145 mm

(L x W x H) 

4.5 x 4.5 x 5.7 inches

Weight

241 g (8.50 oz lbs) without 
battery

Rainfall unit

Mm/hr and in/hr

Range

0 mm/hr – 9999 mm/hr

Resolution

1 mm/hr

Accuracy

< 15 mm/hr: +/- 1 mm
15 mm to 9999 mm: +/- 7%

Memory

Past 24hrs, hourly and 
accumulated
from last memory reset

Battery

2 x UM-3 (AA) 1.5V

PRECAUTIONS

•  Do  not  subject  the  unit  to  excessive  force,  shock, 

dust, temperature or humidity.

•  Do not cover the ventilation holes with any items such 

as newspapers, curtains etc.

•  Do not immerse the unit in water. If you spill liquid 

over it, dry it immediately with a soft, lint-free cloth.

•  Do  not  clean  the  unit  with  abrasive  or  corrosive 

materials. 

•  Do not tamper with the unit’s internal components. 

This invalidates the warranty.

•  Only  use  fresh  batteries.  Do  not  mix  new  and  old 

batteries.

•  Images  shown  in  this  manual  may  differ  from  the 

actual display.

•  When disposing of this product, ensure it is collected 

separately for special treatment and not as household 
waste.

•  Placement of this product on certain types of wood 

may result in damage to its finish for which Oregon 
Scientific will not be responsible. Consult the furniture 
manufacturer's care instructions for information.

•  The contents of this manual may not be reproduced 

without the permission of the manufacturer.

•  Do not dispose old batteries as unsorted municipal 

waste.  Collection of such waste separately for special 
treatment is necessary.

•  Please  note  that  some  units  are  equipped  with  a 

battery safety strip. Remove the strip from the battery 
compartment before first use.

 NOTE 

 The technical specifications for this product and 

the contents of the user manual are subject to change 
without notice.

 NOTE 

 Features and accessories will not be available 

in  all  countries.    For  more  information,  please  contact 
your local retailer.

ABOUT OREGON SCIENTIFIC

Visit  our  website  (www.oregonscientific.com)  to  learn 
more  about  Oregon  Scientific  products.  If  you're  in 
the  US  and  would  like  to  contact  our  Customer  Care 
department directly, please visit: www2.oregonscientific.
com/service/support.asp

For  international  inquiries,  please  visit:  www2.
oregonscientific.com/about/international.asp 

EU DECLARATION OF CONFORMITY

Hereby, Oregon Scientific, declares that this Advanced 
Weather Station with Wireless Sensor Set & Mounting 
Package  (models:  WMR100N  /  WMR100NA)  is  in 
compliance  with  the  essential  requirements  and  other 
relevant provisions of Directive 1999/5/EC. A copy of the 
signed and dated Declaration of Conformity is available 
on request via our Oregon Scientific Customer Service.

COUNTRIES RTTE APPROVAL COMPLIED

All EU countries, Switzerland

and Norway    

CH

N

Содержание WMR100N

Страница 1: ...ainfall 12 Weather Alarms 12 Set Up Software First time use 12 Additional step for Windows Vista users only 12 Install software 13 Disable Sleep Mode 13 To disable sleep mode on computer 13 Windows XP...

Страница 2: ...ity or UV readings in various locations Optional wireless remote sensors such as those listed below can be purchased separately For more information please contact your local retailer Solar Panel STC8...

Страница 3: ...a 1 2 3 4 5 6 7 8 9 1 Temperature trend 2 Wind Chill level temperature is showing 3 Heat Index level temperature is showing 4 HI LO temperature HI Heat Index and LO Wind Chill alarms are set 5 Selecte...

Страница 4: ...1 Clock radio reception 2 Alarm 1 and 2 are displayed and set 3 Timestamp is displayed 4 Offset time zone 5 Moon phase 6 Time date calendar Humidity Dew Point Area 1 2 3 4 5 6 1 Dew point level Temper...

Страница 5: ...anemometer from the wind sensor carefully 2 Insert batteries matching the polarities and replace the anemometer Press RESET after each battery change 3 3 Slide wind vane onto the end of the plastic at...

Страница 6: ...ment bracket on top of the top pole 11 Using two screws x it rmly into place To mount the temperature humidity sensor 12 12 Slide outdoor sensor onto vertical attachment bracket To mount the wind sens...

Страница 7: ...00 meters 328 feet in an open area The rain gauge should be mounted horizontally about 1 meter 3 feet from the ground in an open area away from trees or other obstructions to allow rain to fall natura...

Страница 8: ...hange the display and settings use the following buttons on the rotating dial SELECT MEMORY ON OFF MODE and ALARM In addition the UNIT and SEARCH buttons located at the bottom of the base station allo...

Страница 9: ...2 is displayed Alarm 1 or 2 is activated No icons No alarm is set To set an alarm 1 Press SELECT to navigate to the Clock Area will show next to the Area 2 Press ALARM to toggle between alarm 1 and a...

Страница 10: ...Index MAX Wind Chill 1 only MIN Humidity Humidity Indoor and 1 10 outdoor MAX MIN Dew Point MAX MIN The timestamp is displayed accordingly in the Clock Area To clear the memories and timestamp for the...

Страница 11: ...te or deactivate the alarm UVI BAROMETER RAINFALL The weather station works with one UV sensor and one rain gauge The station is capable of storing and displaying the hourly history data for the last...

Страница 12: ...l reading display Press and hold MEMORY ON OFF to reset the accumulated rainfall to 0 and to set the timestamp to current date and time To change the HI rainfall rate alarm 1 In the UV Barometer Rainf...

Страница 13: ...1 Right click on Desktop 2 In context menu click on Properties 3 Click on Screen Saver tab in the Display Properties dialogue box 4 Click on Power located at the bottom half of dialogue box 5 In new d...

Страница 14: ...level User setting for compensation Weather display Sunny Partly Cloudy Cloudy Rainy and Snowy Memory Historical data and bar chart for last 24hrs INDOOR TEMPERATURE Temp unit C F Displayed range 0 C...

Страница 15: ...this product ensure it is collected separately for special treatment and not as household waste Placement of this product on certain types of wood may result in damage to its nish for which Oregon Sci...

Страница 16: ...ion reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the re...

Отзывы: