background image

EN

7

3.

Place the sensor near the main unit. Press 

RESET

on the sensor to initiate signal sending between the
sensor and the main unit. The reception icon on
the main unit will blink for approximately 3 minutes
while it is searching for the sensor. (Refer to the

Search for Sensor

 section for more information.)

4.

Close the remote sensor battery compartment.

5.

Secure the sensor in the desired location using the
wall mount or table stand.

1.

Insert the batteries, matching the polarity as shown
in the battery compartment.

2.

Set the channel. The switch is located in the battery
compartment.

SWITCH

OPTION

Channel

Channel 1 - 3. If you are using
more than one sensor, select a
different channel for each sensor.

For best results:

• Insert the batteries and select the channel and

temperature unit before you mount the sensor.

• Place the sensor out of direct sunlight and

moisture.

• Do not place the sensor more than 30 meters

(98 feet) from the main (indoor) unit.

• Position the sensor so that it faces the main

(indoor) unit, minimizing obstructions such as
doors, walls, and furniture.

• Place the sensor in a location with a clear view

to the sky, away from metallic or electronic
objects.

• Position the sensor close to the main unit during

cold winter months as below-freezing
temperatures may affect battery performance
and signal transmission.

You may need to experiment with various locations to
get the best results.

DATA TRANSMISSION

Data is sent from the sensor(s) every 40 seconds.
The reception icon shown in the Temperature and
Humidity Areas show the status.

RMR613HGA lab test R2

1/17/04, 5:00 PM

7

Содержание RMR613HGA

Страница 1: ...Wireless Thermo Hygro Clock Model RMR613HGA User Manual RMR613HGA lab test cover R2 1 8 04 7 02 PM 1...

Страница 2: ...9 Set Clock 9 Switch Clock Display 9 Alarms 9 View Alarm Settings 9 Set Alarm 9 Activate Alarm 10 Silence Alarm 10 Temperature and Humidity 10 Select Temperature Unit 10 Select Sensor Channel 10 Minim...

Страница 3: ...X Keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know ABOUT OREGON SCIENTIFIC Visit our...

Страница 4: ...status 2 Temperature Area Readings sensor channel number remote unit reception and battery status 3 Humidity Comfort Zone Area Readings comfort zone and battery status 4 Channel button switch remote...

Страница 5: ...crease setting deactivate radio controlled clock activate or deactivate alarm 3 UP increase setting activate radio controlled clock activate or deactivate alarm 4 MODE change display settings 5 Batter...

Страница 6: ...SENSOR THGR122NX 1 LCD display 2 LED Status indicator 1 2 1 2 3 4 1 Wall mount hole 2 RESET 3 Channel number 1 3 4 Battery compartment Battery compartment cover not shown RMR613HGA lab test R2 1 17 0...

Страница 7: ...ED BATTERIES Batteries are not supplied with this product You will need to purchase 2 x UM 3 AA 1 5V alkaline batteries for the main unit and 2 x UM 4 AAA 1 5V alkaline batteries for the remote sensor...

Страница 8: ...ach sensor For best results Insert the batteries and select the channel and temperature unit before you mount the sensor Place the sensor out of direct sunlight and moisture Do not place the sensor mo...

Страница 9: ...for the sensor or check batteries NOTE CLOCK This product can track the date and time for up to 2 locations Clock with Offset Hour The US Atomic Clock in Boulder Colorado automatically updates this in...

Страница 10: ...t the Atomic Clock feature is ON No icon means that it is OFF SWITCH CLOCK DISPLAY Press MODE to toggle between Clock with Seconds Clock with Weekday and Calendar and Clock with Offset Hour display AL...

Страница 11: ...y The SingleAlarm will not sound unless you manually activate it again TEMPERATURE AND HUMIDITY This product can display the following information from the remote sensors VIEW BAROMETER AREA Current m...

Страница 12: ...t temperature and humidity measurements NOTE ZONE TEMPERATURE HUMIDITY Any 70 20 25 C 68 77 F 40 70 40 Any This information is shown in the Humidity Area when the current measurement is displayed RESE...

Страница 13: ...duct with a slightly damp cloth and alcohol free mild detergent Avoid dropping the product or placing it in a high traffic location WARNINGS This product is designed to give you years of service if ha...

Страница 14: ...SENSOR DIMENSIONS L x W x H 92 x 60 x 20 mm 3 6 x 2 4 x 0 79 inches Weight 63 grams 2 22 ounces without battery TEMPERATURE Unit C or F Indoor Range 5 C to 50 C 23 F to 122 F Outdoor Range 20 C to 60...

Страница 15: ...he FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy...

Страница 16: ...hone No 1 800 853 8883 Fax No 1 503 684 8883 declare that the product Product No RMR613HGA Product Name Wireless Thermo Hygro Clock Manufacturer IDT Technology Limited Address Block C 9 F Kaiser Estat...

Страница 17: ...P N 086 003326 01 2004 Oregon Scientific All rights reserved RMR613HGA lab test back cover 12 29 03 10 49 PM 1...

Отзывы: