Remote Unit: -20 ˚C to 60 ˚C (-4 ˚F
to 140 ˚F)

Resolution

0.1 

°

C (0.2

°

 F)

Comfort

20 

°

C to 25 

°

C (68 

°

F to 77 

°

F)

(see also, Relative humidity)

Memory

Minimum / maximum

Trend

+/- 0.5 ˚C (+/- 0.9 ˚F) change

Relative humidity

Range

Main & Remote Unit: 25% to 95%

Resolution

1%

Comfort

40% to 70%
(see also, Temperature)

Memory

Minimum / maximum

Trend

3% change

Barometer

Unit

mb/hPa or inHg

Range

500 to 1050mb
(14.77 to 31.01 inHg)

Resolution

1mb (0.03 inHg)

Altitude

-100 to 2500 meters (-328 to 8202
feet)

Display

Rainy, cloudy, partly cloudy, sunny

Memory

24 hour

Trend

1mb change in 1 hour or 3mb

change in 6 hours

Remote unit

RF frequency

433 MHz

Range

30 meters (98 feet) with no

obstructions

Transmission

approximately every 40 seconds

25

PS-L06_GB-final.p65

8/8/03, 12:03 PM

27

Содержание PSL06A

Страница 1: ...EN Full Weather Station with Radio Controlled Clock Projection and AM FM Radio Model PS L06 PS L06U User Manual PS L06_GB final p65 8 8 03 12 02 PM 1...

Страница 2: ...EN PS L06_GB final p65 8 8 03 12 02 PM 2...

Страница 3: ...es 9 Change settings 9 Remote unit setup 9 Clock 10 Alarm 11 Calendar 12 Moon phase 13 Barometer 13 Weather forecast 15 Temperature humidity 15 Radio 18 Backlight 19 Projector 20 Reset system 21 Safet...

Страница 4: ...less outdoor tempera ture and humidity monitoring weather forecasting projection and digital AM FM radio into a single tool you can use from the convenience of your home Keep this manual handy as you...

Страница 5: ...EN PRODUCT OVERVIEW TOP VIEW DESCRIPTIONS 1 Snooze Light button 12 19 2 Light sensor 19 3 Projection lens 20 1 2 3 3 PS L06_GB final p65 8 8 03 12 02 PM 5...

Страница 6: ...RIPTIONS 1 Low batteries icon 8 2 Clock 10 3 Barometer 13 4 Weather forecast 15 5 Moon phase 13 6 Calendar 12 7 Temperature and humidity 15 8 Alarm 11 9 Radio 18 1 2 3 4 6 9 8 7 5 4 PS L06_GB final p6...

Страница 7: ...ctivate auto synch 11 5 Down decrease setting deactivate auto synch 11 6 Alarm activate deactivate alarm 12 7 Channel switch remote unit 16 8 Radio turn radio or radio alarm on off 12 18 9 Station sel...

Страница 8: ...ttery compartment 8 2 Light sensitivity knob 20 3 Reset button 8 21 4 Antenna 18 5 Headphone jack 19 6 DC power input jack 8 7 Backlight switch 19 NOTE AC power adapter not shown 6 3 2 1 4 5 6 7 PS L0...

Страница 9: ...rend display 2 Low battery icon 3 Humidity Trend Comfort Level display 4 C F switches 5 Channel switches 6 Reset button 7 Battery compartment 8 Wall mount hole 9 Battery compartment lid 7 7 9 2 3 6 4...

Страница 10: ...partment Before you close the lid press the RESET button with the point of a blunt object such as a ball point pen NOTE Insert the batteries in the remote unit before you set up the main unit Do not u...

Страница 11: ...2 or 3 switches are located in the battery compartment and should be set prior to installation NOTE Additional remote units sold separately If you are using more than one remote unit be sure to select...

Страница 12: ...me keeping organizations in Frankfurt Germany PS L06 or Rugby England PS L06U When the unit is within 1500 km 932 miles of a RF signal the reception icon will blink during reception RECEPTION Receptio...

Страница 13: ...format hour and minute Press UP or DOWN to change the setting Press SELECT to confirm ALARM When activated the Melody Alarm starts quietly then gradually becomes louder It shuts off after two minutes...

Страница 14: ...inutes The alarm icon will blink while Snooze is activated TO TURN THE ALARM OFF OR ON Press RADIO to turn the radio alarm off Press any other button to turn the melody alarm off To turn the alarm off...

Страница 15: ...E Press SELECT until the Calendar Area flashes Then press UP or DOWN to change the date and view the corresponding moon phase BAROMETER This product tracks barometric pressure changes over the past 24...

Страница 16: ...nd altitude Setting the altitude allows the product to take more accurate barometric measurements 1 Press SELECT 2 times until the Barometer Area flashes 2 Press and hold SELECT for 2 seconds 3 Select...

Страница 17: ...ty percentage comfort level trend and record measurements Outdoor measurements are collected by the remote unit Temperature is give at the top humidity is below VIEW MIN MAX CURRENT MEASUREMENTS Press...

Страница 18: ...2 seconds again SENSOR SEARCHING If there is no remote unit signal the temperature and humidity measurement will be blank Check the remote unit batteries or press and hold UP and DOWN for 2 seconds to...

Страница 19: ...r the last 30 minutes always displays Indoor and outdoor temperature and humidity trends are shown separately 17 Zone Temperature Relative Humidity Wet Dry Comfort Any 20 25 C 68 77 F 70 40 40 70 Any...

Страница 20: ...ception TURN THE RADIO ON OR OFF Press the RADIO button VOLUME Press UP or DOWN There are 8 volume levels SWITCH AM FM BAND Press TUNING to enable auto tuning Press again to switch AM FM band SELECT S...

Страница 21: ...headphones for stereo quality radio listening BACKLIGHT Press SNOOZE LIGHT to illuminate the backlight for 5 seconds CONTINUOUS BACKLIGHT The AC power adapter must be plugged in to use this feature 8...

Страница 22: ...night NOTE The maximum projection range is 2 meters 6 feet The image gets larger the farther you display it PROJECT TIME ALARM STATUS In a darkened room press SNOOZE LIGHT to display the time and alar...

Страница 23: ...with the tip of a blunt object such as a ball point pen whenever you change the batteries or whenever performance is not behaving as expected e g unable to establish radio frequency link with remote...

Страница 24: ...Do not use rechargeable batteries with this product Remove the batteries if storing this product for a long period of time Do not scratch the LCD display Do not make any changes or modifications to t...

Страница 25: ...Check sensors Only one sensor is working 16 Adjust the antenna 18 Problem Symptom Remedy Clock Cannot auto synchronize 1 Remove batteries 2 Press reset All memory items will return to default 3 Replac...

Страница 26: ...ches Weight 136 grams with battery Temperature Unit C or F Range Main unit 5 C to 50 C 23 F to 122 F 24 Problem Symptom Remedy Cannot change clock Disable auto synchronization 11 Baro Strange reading...

Страница 27: ...Temperature Memory Minimum maximum Trend 3 change Barometer Unit mb hPa or inHg Range 500 to 1050mb 14 77 to 31 01 inHg Resolution 1mb 0 03 inHg Altitude 100 to 2500 meters 328 to 8202 feet Display Ra...

Страница 28: ...lody or radio 2 minute crescendo melody only Snooze 8 minutes melody only Radio Type Digital tuning PLL Phase Lock Loop stereo Band 531 to 1602 kHz AM 87 5 to 108 0 MHz FM Stations 8 AM 8 FM Volume 8...

Страница 29: ...tteries ADDITIONAL RESOURCES Visit our website www oregonscientific com to learn more about your new product and other Oregon Scientific products such as digital cameras hand held organizers health an...

Страница 30: ...he R TTE Directive applied standard s ETSI EN 301 489 1 3 Ver 1 4 1 2002 08 Safety of information technology equipment Article 3 1 a of the R TTE directive applied standard s EN 60950 2000 RTT E Compl...

Отзывы: