background image

8

EN

GETTING STARTED

BATTERIES

Batteries for the remote and main units are supplied
with this product. Replace them whenever the low
battery signal ( 

 ) displays. Slide open the battery

door at the back of the main unit. Use a small
Phillips screwdriver to remove the remote unit
compartment lid.  Be sure to match the correct
polarity, as shown in the battery compartment.  After
you change the batteries, press the RESET button
with the point of a blunt object (such as a ball point
pen).

Insert the batteries in the remote unit before

you set up the main unit.  Do not use rechargeable
batteries.

CHANGE SETTINGS

Press and hold CLOCK or ALARM for 2 seconds to
enter setting mode.  Then, press 

s

 UP or 

t

 DOWN

to change each setting.  Press and hold to enter
fast-setting mode. Press CLOCK or ALARM to
switch between settings.

Содержание Monza FAW-101

Страница 1: ...Getting started 8 Batteries 8 Change settings 8 Remote unit setup 9 Clock 10 Alarm 12 Barometer 13 Weather forecast 13 Temperature humidity 14 Backlight 17 Reset system 17 Safety and care 18 Warnings 18 Troubleshooting 19 Specifications 21 Additional resources 23 ...

Страница 2: ...itoring indoor and wireless outdoor temperature and humidity measurement time keeping and alarm features into a single tool you can use from the convenience of your home Keep this manual handy as you use your new product It contains practical step by step instructions as well as technical specifications and warnings you should know In this box you will find Main unit Remote sensor Batteries ...

Страница 3: ...3 EN PRODUCT OVERVIEW TOP VIEW DESCRIPTIONS A Snooze Light button 12 17 B Altitude button 13 1 2 ...

Страница 4: ... 3 Road conditions 14 4 Temperature Trend 14 17 5 Remote unit signal reception 15 6 Remote unit Low Battery icon 8 7 Humidity Trend 14 17 8 Barometer 13 9 Alarm Status Type 12 10 Clock Calendar 10 11 RF Signal Reception 10 12 Racing Car Animation 1 2 3 4 5 6 7 8 9 10 11 12 ...

Страница 5: ...EN FRONT VIEW DESCRIPTIONS 1 Clock 10 2 Alarm 12 3 s UP t DOWN increase decrease setting or activate deactivate auto synchronization 8 11 4 Channel switch remote unit 15 5 Memory view memory 15 1 2 3 4 5 ...

Страница 6: ...EW DESCRIPTIONS 1 Battery compartment 8 2 C F switch 9 16 3 Reset button 17 4 Radio format switch 10 5 Barometer unit switch 13 6 Table Stand EU UK C F RESET AA UM 31 5V AA UM 31 5V AA UM 31 5V mb inhg 1 2 3 4 5 6 ...

Страница 7: ...DESCRIPTIONS 1 Temperature 14 2 Humidity and comfort level 14 16 3 Channel number 9 15 4 LED Indicator 15 5 C F switch 9 15 6 Reset button 17 7 Channel switch 9 15 8 Batteries 8 9 Battery compartment 8 1 2 3 4 5 6 7 8 9 ...

Страница 8: ...match the correct polarity as shown in the battery compartment After you change the batteries press the RESET button with the point of a blunt object such as a ball point pen Insert the batteries in the remote unit before you set up the main unit Do not use rechargeable batteries CHANGE SETTINGS Press and hold CLOCK or ALARM for 2 seconds to enter setting mode Then press s UP or t DOWN to change e...

Страница 9: ...than one remote unit be sure to select a different channel number for each unit INSTALLATION Mount the remote unit on a flat surface using the recess holes on the back of the unit For best results Insert the batteries and select the measurement unit and channel number first Place the unit out of direct sunlight and moisture Do not place the remote unit more than 20 30 meters 60 90 feet from the ma...

Страница 10: ...t Germany and Rugby England When the unit is within 1500 km 932 miles of a RF signal the reception icon will blink during reception SET RADIO SIGNAL FORMAT The RADIO SIGNAL FORMAT switch is located in the battery compartment Select EU DCF or UK MSF Then press RESET to reset the unit Reception takes 2 10 minutes to complete Once complete the icon will stop blinking Strong signal Weak signal No sign...

Страница 11: ...ate the synchronization To enable auto reception press s UP for 2 seconds SET OR CHANGE THE CLOCK Auto synchronization must be deactivated before you manually set the clock previous section 1 Press and hold CLOCK for 2 seconds to enter setting mode 2 Select the 12 24 hour format hour minute year date month format month date and display language Press s UP or t DOWN to change the setting Press CLOC...

Страница 12: ...p for the first 5 seconds SET ALARM 1 Press and hold ALARM for 2 seconds to enter setting mode 2 Select the hour minute and alarm type for Beep Alarm or for Ferrari Engine Press s UP or t DOWN to change the setting Press ALARM to confirm SNOOZE Press SNOOZE LIGHT to temporarily disable the alarm for 8 minutes The alarm icon will blink while Snooze is activated TO TURN THE ALARM OFF OR ON Press CLO...

Страница 13: ...y the main indoor unit SET UNIT AND ALTITUDE You can set the unit of measurement mb hPa or inHg and altitude Setting the altitude allows the product to take more accurate barometric measurements 1 The Barometer Unit switch is located on the back of the product Select mb hPa or inHg 2 To set the altitude press and hold ALT for 2 seconds Press s UP or t DOWN to change the setting Press ALT to confir...

Страница 14: ... wheel icon will indicate the predicted road conditions Dry Slick Very Wet TEMPERATURE AND HUMIDITY With the press of a button you can check the current indoor or outdoor temperature humidity percentage comfort level trend and record measurements Outdoor measurements are collected by the remote unit Clear Cloudy Rainy Partly Cloudy ...

Страница 15: ... or indoor Or press and hold for 2 seconds to enter auto scan mode If you select Auto the channel will change every 3 seconds Press CHANNEL or MEMORY again to deactivate this Auto function SENSOR SEARCHING Simultaneously press CHANNEL and MEMORY to manually activate channel searching The search icon will blink until the remote signal is found or the search period times out No signal Searching Stro...

Страница 16: ...erformance of the product Reception will automatically resume once the interference ends Check the remote unit batteries if no signal is found SET UNIT The C F switch is located on the back of the main unit and in the battery compartment for the remote unit Select C or F COMFORT ZONE The indoor and outdoor comfort zones are always shown Zone Temperature Relative Humidity Com 20 25 C 68 77 F 40 70 ...

Страница 17: ...ET SYSTEM The RESET button are located on the back of the main unit and in the battery compartment for the remote unit Press these buttons whenever you change the batteries or whenever performance is not behaving as expected e g unable to establish radio frequency link with remote unit or automatic clock etc This will return all settings to default Relative Humidity 0 5 C 3 Steady Steady 0 5 C 3 T...

Страница 18: ...s of service if handled properly Observe the following guidelines Never immerse the unit in water This can cause electrical shock and damage the unit Do not subject the main unit to extreme force shock or fluctuations in temperature or humidity Do not tamper with the internal components Do not mix new and old batteries or batteries of different types Do not use rechargeable batteries with this pro...

Страница 19: ... contents of this user guide are subject to change without notice Images not drawn to scale TROUBLESHOOTING Check here before contacting our customer service department Strange date month Calendar Clock Cannot change clock Disable auto synch 11 Baro Strange reading Set altitude unit 13 Problem Symptom Remedy Change language 11 ...

Страница 20: ...lock Cannot auto synch 1 Adjust batteries 2 Press RESET 17 3 Manually activate auto synch 11 Problem Symptom Remedy Temperature is out of range Problem Symptom Remedy Cannot change channel Check location 9 Check sensors Only one sensor is working 15 Remote unit Cannot locate remote unit ...

Страница 21: ...th batteries Remote unit dimensions L x W x H 92 x 60 x 20 mm 3 6 x 2 4 x 0 8 inches Weight 100 grams 0 2 lb Temperature Unit C or F Indoor Range 5 C to 50 C 23 F to 122 F Outdoor Range 20 C to 60 C 4 F to 140 F Resolution 0 1 C 0 2 F Comfort 20 C to 25 C 68 F to 77 F Memory Minimum maximum Trend 0 5 C change per 30 minutes ...

Страница 22: ...Hg Range 500 to 1050 mb 14 77 to 31 01 inHg Resolution 1 mb 0 03 inHg Altitude 100 to 2500 meters 328 to 8202 feet Display Rainy cloudy partly cloudy sunny Remote unit RF frequency 433 MHz Range 30 meters 98 feet with no obstructions Transmission every 40 seconds Channel No 1 2 or 3 Unit C or F Radio controlled clock Synchronization Auto or disabled ...

Страница 23: ...ower Main unit 3 x UM 3 AA 1 5V alkaline batteries Remote unit 2 x UM 4 AAA 1 5V alkaline batteries ADDITIONAL RESOURCES Visit our website www oregonscientific com to learn more about your new product and other Oregon Scientific products such as digital cameras hand held organizers health and fitness gear and weather stations The website also includes contact information for our customer service d...

Страница 24: ...patibility Article 3 1 b of the R TTE Directive applied standard s ETS300683 1997 Safety of information technology equipment Article 3 1 a of the R TTE directive applied standard s EN60950 1997 Additional information The product is therefore conform with the LowVoltage Directive 73 23 EC the EMC Directive 89 336 EC and R TTE Directive 1999 5 EC appendix II and carries the respective CE marking VS ...

Страница 25: ...Wireless Weather Station Model FAW 101 Monza User Manual O R E G O N S C I E N T I F I C ...

Отзывы: