Full Range

The comfort indicators will appear on the display when the
following conditions are satisfied:

Indicator

Temperature

Humidity

Shows that the

displays

Range

Range

Current

on the unit

Environment

COMFORT 20°C to 25°C

40% RH to

Ideal range for

(68°F to 77°F)  70% RH

both relative

humidity and
temperature

WET

Over

Contain excess

70%RH

moisture.

DRY

Below

Contain

40%RH

inadequate
moisture

 No

Less than

40%RH

No comment

Indicator

20°C(68°F)  or      to
More than

70%RH

25°C(77°F)

HOW TO SELECT THE

TEMPERATURE THE UNITS OF

MEASURE

The switch on the back of the Barometer selects between
degrees Celsius and Fahrenheit. To select Celsius units, set
the switch to °C. To select Fahrenheit units, set the switch to
°F.

HOW TO SELECT THE PRESSURE

UNITS OF MEASURE

The switch on the back of the Barometer selects between mb
/ hPa and inHg. To select mb / hPa , set the switch to mb / hPa.
To select inHg, set the switch to inHg.

THE RESET BUTTON

If the unit does not operate properly, use a pointed object to
push the [ RESET ] button once, which is located on the back
of the unit.

Содержание BA-116

Страница 1: ...ion Wall mounting and table standing features INSTRUCTION MANUAL Model BA 116 Electronic Barometer Thank you for purchasing the Oregon Scientific barometer This barometer has been designed specificially with performance and ease of use in mind As with all Oregon Scientific products this barometer is made to the highest quality standards using precision electronic components and should give you man...

Страница 2: ...es as indicated by the polarity symbols and marked inside the battery compartment 3 Replace the battery compartment cover Note After replacing the batteries the whole display will be turned on for about 3 seconds and then show the following a Indoor temperature shows the current reading b Indoor relative humidity shows the current reading c Weather forecast shows slightly cloudy a sun shows with t...

Страница 3: ...cent and therefore we cannot be held responsible for any inconveniences caused by an inaccurate weather forecast 2 The weather forecast symbols may not reflect the current weather condition The symbols are forecasting the future 3 A Sunny forecast covering the night time reflects fine clear weather HOW TO READ THE BAR GRAPH PRESSURE TREND Stored memory of the barometric pressure changes are displa...

Страница 4: ...sidered to be about 70 75 ABOUT THE ALTITUDE SETTING 1 For monitoring the local barometric pressure reading the user needs to select the 0 meter preset value for the altitude setting 2 FormonitoringtheSeaLevelbarometricpressurereading at certain altitude the user needs to select the local altitude 100 to 2500 meter for the altitude setting HOW TO SET THE ALTITUDE 1 Press and hold the ALT button fo...

Страница 5: ... displayed for each hour 1 By pressing the HISTORY button repeatedly the barometric pressure readings which have been stored over the past 24 hours will appear on the display in mb hPa or inHg with the recording time up to 24 hour and back to 0 hour 0 hour means present time 2 Press and hold the HISTORY button for faster advancing 3 If the pressure in one particular history hour has not yet been r...

Страница 6: ...o comment Indicator 20 C 68 F or to More than 70 RH 25 C 77 F HOW TO SELECT THE TEMPERATURE THE UNITS OF MEASURE The switch on the back of the Barometer selects between degrees Celsius and Fahrenheit To select Celsius units set the switch to C To select Fahrenheit units set the switch to F HOW TO SELECT THE PRESSURE UNITS OF MEASURE The switch on the back of the Barometer selects between mb hPaand...

Страница 7: ...Y Wall Mount On the back of the Barometer you ll find a recess holes for wall handing Place a screw or whatever device you choose into the wall until the head extends a little more than 4 mm from the wall Place your barometer over the screw in the hanger slot until it locks into place MAINTENANCE The following suggestions will help you care for the Barometer so you can enjoy it for years 1 Keep th...

Страница 8: ...c circuits 7 Modifying or tampering with the Barometer s internal components can cause a malfunction and might invalidate its warranty SPECIFICATION Operating temperature 0 C to 55 C 32 F to 131 F Temperature measuring range 0 C to 55 C 32 F to 131 F Temperature display resolution 1 C 2 F Temperature sampling cycle 9 seconds Humidity measuring range 25 to 95 RH at 25 C 77 F Humidity display resolu...

Страница 9: ...ays shown in this manual may differ from the actual displays The manufacturer and its supplies held no respond to you or any other person for any damages expenses lost profits or any other damages arise by using this Barometer The contents of this manual may not be reproduced without the permit of the manufacturer ...

Отзывы: