HOW TO SELECT THE BAR OR LINE

CHART FOR THE PRESSURE TREND

In bar chart display, press and hold the [ ALT ] button and
then reset the unit by pressing the [ RESET ] button on the
back of the unit simultaneous, to get the line chart display.

LINE CHART

BAR CHART

In line chart display, reset the unit by pressing the
[ RESET ] button once on the back of the unit to get
the bar chart display.

Note:

Either action will reset the unit and the previous
readings / settings will be lost.

HOW TO RECALL THE STORED

PRESSURE HISTORY READING

The barometric pressure reading is being stored constantly
during the past 24 hours. It can be recalled and displayed for
each hour.

1. By pressing the [ HISTORY ] button repeatedly, the

barometric pressure readings which have been stored
over the past 24 hours, will appear on the display in
mb/hPa or inHg with the  recording time up to ‘  -24  ‘
hour and back to ‘ 0 ‘ hour. ( ' 0 ' hour means present
time ).

2. Press and hold the [ HISTORY ] button , for faster

advancing.

3. If the pressure in one particular history hour has not yet

been recorded, it will show ‘  - - - - ‘  for that hour on the
past history review display.

UNITS OF
MEASURE

PRESSURE READING

PAST PRESSURE

HISTORY

IN ' HOUR '

HOW TO READ THE RELATIVE

HUMIDITY AND THE COMFORT

INDICATORS

The unit shows the indoor relative humidity automatically
and such reading is temperature compensated. At the same
time, the comfort indicators - COMFORTWET or DRY will
tell you if the current environment is comfortable, too wet or
too dry.

Содержание BA-116

Страница 1: ...ion Wall mounting and table standing features INSTRUCTION MANUAL Model BA 116 Electronic Barometer Thank you for purchasing the Oregon Scientific barometer This barometer has been designed specificially with performance and ease of use in mind As with all Oregon Scientific products this barometer is made to the highest quality standards using precision electronic components and should give you man...

Страница 2: ...es as indicated by the polarity symbols and marked inside the battery compartment 3 Replace the battery compartment cover Note After replacing the batteries the whole display will be turned on for about 3 seconds and then show the following a Indoor temperature shows the current reading b Indoor relative humidity shows the current reading c Weather forecast shows slightly cloudy a sun shows with t...

Страница 3: ...cent and therefore we cannot be held responsible for any inconveniences caused by an inaccurate weather forecast 2 The weather forecast symbols may not reflect the current weather condition The symbols are forecasting the future 3 A Sunny forecast covering the night time reflects fine clear weather HOW TO READ THE BAR GRAPH PRESSURE TREND Stored memory of the barometric pressure changes are displa...

Страница 4: ...sidered to be about 70 75 ABOUT THE ALTITUDE SETTING 1 For monitoring the local barometric pressure reading the user needs to select the 0 meter preset value for the altitude setting 2 FormonitoringtheSeaLevelbarometricpressurereading at certain altitude the user needs to select the local altitude 100 to 2500 meter for the altitude setting HOW TO SET THE ALTITUDE 1 Press and hold the ALT button fo...

Страница 5: ... displayed for each hour 1 By pressing the HISTORY button repeatedly the barometric pressure readings which have been stored over the past 24 hours will appear on the display in mb hPa or inHg with the recording time up to 24 hour and back to 0 hour 0 hour means present time 2 Press and hold the HISTORY button for faster advancing 3 If the pressure in one particular history hour has not yet been r...

Страница 6: ...o comment Indicator 20 C 68 F or to More than 70 RH 25 C 77 F HOW TO SELECT THE TEMPERATURE THE UNITS OF MEASURE The switch on the back of the Barometer selects between degrees Celsius and Fahrenheit To select Celsius units set the switch to C To select Fahrenheit units set the switch to F HOW TO SELECT THE PRESSURE UNITS OF MEASURE The switch on the back of the Barometer selects between mb hPaand...

Страница 7: ...Y Wall Mount On the back of the Barometer you ll find a recess holes for wall handing Place a screw or whatever device you choose into the wall until the head extends a little more than 4 mm from the wall Place your barometer over the screw in the hanger slot until it locks into place MAINTENANCE The following suggestions will help you care for the Barometer so you can enjoy it for years 1 Keep th...

Страница 8: ...c circuits 7 Modifying or tampering with the Barometer s internal components can cause a malfunction and might invalidate its warranty SPECIFICATION Operating temperature 0 C to 55 C 32 F to 131 F Temperature measuring range 0 C to 55 C 32 F to 131 F Temperature display resolution 1 C 2 F Temperature sampling cycle 9 seconds Humidity measuring range 25 to 95 RH at 25 C 77 F Humidity display resolu...

Страница 9: ...ays shown in this manual may differ from the actual displays The manufacturer and its supplies held no respond to you or any other person for any damages expenses lost profits or any other damages arise by using this Barometer The contents of this manual may not be reproduced without the permit of the manufacturer ...

Отзывы: