8
Position
Table a curve
speed
DIP switch position
Air output
Pressure
Power
consumption
Setting
Qv
Pf
Pe
(Number)
1
2
3
4
5
6
7
[m
3
/h]
[Pa]
[W]
Absent
0
-
-
-
-
-
-
-
45
5
2
*Low
1a
Off
-
-
-
-
-
Off 70
10
3
Low
2a
On
-
-
-
-
-
Off 85
14
4
*Medium
3a
-
Off
Off
Off
-
-
Off 150
46
7
Medium
4a
-
On
Off
Off
-
-
Off 171
62
9
Medium
5a
-
Off
On
Off
-
-
Off 197
81
12
Medium
6a
-
On
On
Off
-
-
Off 222
101
15
Medium
7a
-
Off
Off
On
-
-
Off 245
123
20
Medium
8a
-
On
Off
On
-
-
Off 270
150
27
Medium
9a
-
Off
On
On
-
-
Off 293
175
32
Medium
10a
-
On
On
On
-
-
Off 316
205
38
*High
11a
-
-
-
-
Off
Off
Off 245
123
20
High
12a
-
-
-
-
On
Off
Off 295
177
33
High
13a
-
-
-
-
Off
On
Off 318
208
40
High
14a
-
-
-
-
On
On
Off 342
241
50
Table A - Table A or B is selected by setting DIP switch 7 to on or off.