19
Change the appliance to the right-hand version:
Step 1 Remove the plug from the socket.
Step 2 Place the unit on a flat surface, if the unit is already hung.
Step 3 Remove both filter handles. Step 4
Remove the plastic front plate.
Step 5 Remove the metal front plate of the unit by loosening the 5 screws. (bit
size T25).
Step 6 Remove the power cord from the cable clamp on the metal back plate.
Step 7 Remove the metal back plate of the unit by removing the 5 screws
(T25).
Step 8 Move the metal front plate to the other side of the unit and retighten
the 5 screws.
Step 9 Move the metal back plate to the back of the unit and retighten the 5
screws.
Step 10 Remove the top circuit board cover by removing the 2 screws. (T25) Note
the length of the display cable when removing the circuit board cover, if
necessary remove it temporarily from the connector on the circuit board.
Step 11 Move the grounding cable to the new back of the device. Also move the
strain relief to the recess on the other side of the PCB.
Step 12 Replace the top cover so that the display is at the front and tighten the
2 screws.
Step 13 Replace the earthed cable in the cable clamp on the metal back plate.
Make sure that the cable does not come under the suspension bracket.
Step 14 Replace the plastic front plate in front of the metal front plate. Then press
the front plate firmly onto the four outer corners.
Step 15 Replace the filter handles.
Содержание 22001090
Страница 1: ......
Страница 2: ...2...
Страница 6: ...index 6...
Страница 16: ...index 16...
Страница 27: ...index 27...
Страница 58: ...index 58 17 Perilex cable HRC 22915405 18 Side earthed cable HRC 22915426...
Страница 60: ...index 60 Only suitable for controlling ventilators U FL R SMT 1 Antenna connector Transformer...
Страница 66: ...index 58 12 400 150 62 126 0 32 13 400 250 79 160 0 40...
Страница 69: ...index 61 Date Activity Initials Overview of maintenance operations Registered RF components Other remarks...
Страница 74: ...Landjuweel 25 3905 PE Veenendaal PO Box 416 3900 AK Veenendaal t 31 0 318 54 47 00 info orcon nl www orcon nl...