1
ENGLISH
One or more stations do
not turn on
Stations turn on when
they are not supposed to
One station is stuck
on and will not shut off
Symptom
Cause
All stations do not turn on
1. Faulty Solenoid
2. Wire broken or not connected
3. Flow control stem screwed down, shutting valve off
4. Programming is incorrect
1. Faulty valve
2. Particles of dirt or debris stuck in valve
3. Valve diaphragm faulty
Timer will not power up
Stations continue to turn on and off
when they are not programmed to
1. Transformer is defective or is not connected correctly
2. Programming is incorrect
3. Timer is in OFF mode
1. Water pressure is too high
2. More than one cycle is programmed
3. Stations are set to water with both programs
1. Transformer is defective or is not connected correctly
2. Transformer not plugged into an operational AC outlet
3. Timer is not all the way down on the docking port.
1. Multiple cycles are programmed.
2. Excessive pressure
3. Stations are set to water with both programs.
4. Water Budgeting is set to more than 100%
Persistant Fault
1. Short in wiring or solenoids
Section 8:
Trouble Shooting
A
A
B
B
Program
Days of Week
Days of Week
Odd/Even
Interval
Watering
Option
1
2
3
4
Station
M, W, Sat
M, W, Sat
Every other day
Every 5 days
Days
5:00 AM
6:45 AM
9:00 PM
Start
Time
15 min
15 min
30 min
30 min
Duration
Minutes
Front Strip
Front, North
Back, North
Front
Location
Spray Heads
Spray Heads
Gear Drive
Shrub Head
Sprinkler
Grass
Grass
Grass
Shrubs and Flowers
Plants