background image

12

 

13

 

• Turn dial to [AUTO]
•  Press the [RAIN DelAY] button to automatically 

delay watering for 24 hours .

•  If a longer Rain Delay is desired, press the [+/–] 

buttons to increase or decrease the setting .

•  Press [eNTeR] or wait 10 seconds and the 

selected rain delay will begin .

•  [CleAR] button stops the rain delay and 

scheduled watering will resume .

•  At the end of the selected rain delay amount of 

time, automatic watering resumes .

•  While in rain delay mode, the timer display 

will switch between the actual time and the 
remaining hours of the delay, every 2 seconds . 

Manual Watering
Your timer has the ability to allow you to manually 
water without disturbing the preset program .

• Turn the dial to [AUTO].
• Press the [MANUAL] button. Display will show 
A B and All . After a few seconds or by pressing 

[eNTeR] the timer will begin manual watering .
•  All stations will water consecutively for their 

programmed duration .

Note: If the run times have not been set, the timer will not 

initiate manual watering and the screen will return to the 

current time. 

•  To specify a specific program or stations, Press the [ 

 

 ] buttons to select A or B .

• Press [ENTER] to activate.
•  To select a specific station, continue pressing 

the [ 

 

 ]buttons until desired station number 

appears .

•  Press the [+/–] to enter the desired duration from 

1 to 240 minutes . 

• Wait 5 seconds and your station will begin.
• To stop Manual Watering press [CLEAR].
•  The timer will go back to your original automatic 

watering schedule . 

Example:

 To manually water on station 3 for five 

minutes, press the [MANUAl] button then press 
the [ 

 

 ] buttons until you see station 3; using 

the [+/–] buttons, set duration to five minutes; 
press [eNTeR] .

Note: After the [MANUAL] button has been pushed, if a 

selection is not made within 5 seconds all stations and 

programs will begin watering using the programmed 

RUN TIMES. If no RUN TIMES have been set, nothing will 

happen and the display will return to the time of day.
Connecting a Rain Sensor

• Connect the rain sensor wires to the wiring 
terminal ports (yellow in color) labeled “sensor” 
(see figure 6) . 

Note: Refer to your rain sensor manual for specific 

wiring instructions.

• Place the sensor on/off switch to the “on” 
position to begin operation .

Rain Sensor Bypass
This sprinkler timer is equipped with a sensor 
override “on/off” switch . This switch is for use during 
maintenance and repairs, so the sprinkler timer can 
be operated even if the rain sensor is in active mode .

Important:

 If the rain sensor switch is in the “on” 

position and no sensor is connected, the sprinkler 

timer will not operate . To resume sprinkler timer 
operation place the switch in the off position .
Replacing the Battery
Your timer requires a CR2032 lithium battery . 

• The battery will maintain your program in case of 
an AC power loss .
• Battery should last approximately one year.
• Open by sliding the battery tray out to the right.

SENSOR COM

24VAC

1 2 3 4

Figure 6: 

Connecting a 

Rain Sensor

Содержание 28954

Страница 1: ...additional instructions Translation Approval Code LB682594 color non printing PMS PMS color non printing PMS Registration K Printers are responsible for meeting print production requirements Any chan...

Страница 2: ...Set Logic simple programming and setup are combined with the latest timer technology and versatility Your new timer provides convenience and flexibility letting you run a fully automatic a semi autom...

Страница 3: ...RROW To go back to the previous setting watering station or move to other programs settings RAIN DELAY To pause operation for 24 72 hours due to rain or other factors To increase a numeric setting To...

Страница 4: ...imum loading for each station pump is 250mA one valve the maximum loading for the timer is 500mA Figure 2 Hang timer on screw using keyhole Keyhole Pre formed mounting holes No 8 Screw Wall 1 8 Figure...

Страница 5: ...commended Remove the plastic strip to activate the pre installed battery See page 12 for battery replacement Note The battery alone will not operate the valves in your sprinkler system The sprinkler t...

Страница 6: ...day an interval of 3 will water every 3rd day etc Odd or Even Days Use the buttons to move to the ODD or EVEN day watering Press or ENTER On this screen the RUN TIME or duration for each station is se...

Страница 7: ...ual Watering press CLEAR The timer will go back to your original automatic watering schedule Example To manually water on station 3 for five minutes press the MANUAL button then press the buttons unti...

Страница 8: ...ed After the first program finishes the next program will begin Rain Delay A feature that postpones the running of a scheduled watering program for a specific duration Solenoid The electrical part on...

Страница 9: ...sponsible for consequential or incidental cost or damage caused by the product failure Orbit liability under this warranty is limited solely to the replacement or repair of defective parts To exercise...

Страница 10: ...nnect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution This appliance is not i...

Страница 11: ...riego previa o moverse a otros programas configuraciones RAIN DELAY Para pausar el funcionamiento durante 24 a 72 horas debido a lluvias u otros factores Para aumentar una configuraci n num rica Para...

Страница 12: ...n forma de bocallave con un tornillo Figura 1 Utilice la plantilla de montaje incluida Figura 3 Cableado de las v lvulas el ctricas Nota La carga m xima para cada estaci n bomba es 250 mA una v lvula...

Страница 13: ...or Enchufe el transformador en un tomacorriente el ctrico de 110 V Consulte la figura 5 5 Active la bater a Se requiere una bater a de litio CR2032 incluida para mantener el programa en la memoria dur...

Страница 14: ...n parpadear para indicar la selecci n La pantalla mostrar la letra del programa A o B Presione los botones para pasar de un d a a otro a trav s de las opciones Presione o ENTER para seleccionar un d...

Страница 15: ...usando los TIEMPOS DE FUNCIONAMIENTO programados Si no se han configurado TIEMPOS DE FUNCIONAMIENTO no suceder nada y la pantalla volver a la hora del d a Conexi n de un detector de lluvia Conecte el...

Страница 16: ...era estaci n programada V LVULA Suministra agua a una estaci n o rea espec ficos La abertura y el cierre de la v lvula se realizan con la corriente el ctrica que suministra el temporizador de regador...

Страница 17: ...ispositivo cumple con la Secci n 15 de las reglas de la FCC El funcionamiento est sujeto a las siguientes dos condiciones 1 Este dispositivo no debe causar interferencia perjudicial y 2 deber aceptar...

Отзывы: