background image

8

9

ENGLISH

says. (For example, in some water districts, watering is 
prohibited on certain days.) To cancel programmed watering on 
specific days of the week, follow these steps:

  Turn the selection dial to 

NO WATERING DAY/PERIOD

. On 

    the display, you will see the seven days of the week with a 
    water drop above each day. The water drop means watering 
    is allowed on that particular day. 

  Press the 

NEXT

 

button to select the day of the week 

    you don’t want to water. (The day will flash.) 

  Press the 

CLEAR

 

button. The water drop above that day 

    will disappear and the “ON” on the bottom right of the  
    display will change to “OFF.” This means the timer will pre-
    vent watering on that day. 

  To unblock a day that has been selected as a no watering day, 

    select the day (following the same steps), then press the 
    

ENTER

 

button. The water drop will reappear and the 

    “OFF” will change to “ON.”

  Exit the “NO WATERING DAY” selection mode by turning 

    the selection dial.

To Prevent Watering During a 

Particular Period of the Day:

There may be a time of the day when you never want the water 
to come on, regardless of what the program calls for. (Perhaps 
your community has banned watering during certain periods 
of the day, or you don’t want your children to get wet going to 
school.) Here’s what to do:

  Turn the selection dial to 

NO WATERING DAY/PERIOD

.

  Press the 

RAIN DELAY

 button. The display reads “SET NO 

    WATER START PERIOD.”

  Press either the 

or 

button to set the start time of the 

    period you don’t want the water to come on. 

  Press the 

ENTER

 

button. The display reads “SET NO 

    WATER END PERIOD.”

  Press either the 

or 

button to set the end time of the 

    period you don’t want the water to come on. 

  Exit the “NO WATERING PERIOD” selection mode by turn-

    ing the selection dial.

NOTE: If programmed watering is interrupted by a no-watering 
period, the timer will resume the watering schedule where it left off 
as soon as the no-watering period is over. If the no-watering period 
prevents scheduled watering from starting, the timer will start the 
watering as soon as the no-watering period is over. This feature is 
called “stacking.”

Set Water Budgeting:

Water Budgeting is a quick way to adjust your set durations (10 
to 200%) based on seasonal requirements.

  Turn the selection dial to 

BUDGETING/LANGUAGE

  Either press the 

button to increase the watering times, or  

    press the 

button to decrease the times in increments  

    of 10 percent. A setting of 100% will not change the set  
    durations, a setting of 200% will increase a 10 minute  

    duration to 20 minutes, and a setting of 10% will decrease a  
    10 minute duration to 1 minute.

  Exit the set water budgeting mode by turning the selection  

    dial.

Test All Stations:

With the “TEST ALL” function, you can easily test all the water-
ing stations by turning them on in sequence for one minute 
each.

  With the dial in the 

AUTO

 position press the 

MANUAL

  

    button. 

  The display reads “TEST ALL” to the right of the letters “A” 

    and “B.”

  Press the 

ENTER

 

button.

Each watering station will turn on for one minute, in sequence. 
To abort this process before the test is finished, press the 

CLEAR

 

button. To advance quickly from one station to 

the next press 

NEXT        

. Otherwise, the timer will automati-

cally exit the “TEST ALL” mode after all stations have run for 
one minute.

Manual Watering - All Stations:

With the “MANUAL ALL” function, you can manually turn on 
the watering stations at any time. 

  With the dial in the 

AUTO

 position press the 

MANUAL

  

    button. 

  Press the 

NEXT

 

button.

  The display reads “MANUAL ALL” to the right of the letters 

    “A” and “B.”

  Press the 

ENTER

 

button.

Each station with a set duration will water in sequence. To 
quickly advance from one station to the next press 

NEXT        

.

To abort this process before the manual watering is finished, 
press 

CLEAR

      

. Otherwise, the timer will automatically exit 

the “MANUAL ALL” mode after all stations have run.

Manual Watering - Program A:

This will allow you to water only those stations with set dura-
tions in Program A. 

  With the dial in the 

AUTO

 position press the 

MANUAL

  

     

    button. 

  Press the 

NEXT

 

button until the display reads    

    “A MANUAL ALL”.

  Press the 

ENTER

 

button.

Each station will water, in sequence, one after another, for the 
same duration specified in Program A. To quickly advance from 
one station to the next press 

NEXT  

      .

To abort this process before the manual watering is finished, 
press 

CLEAR

     

. Otherwise, the timer will automatically 

exit the “A – MANUAL ALL” mode after all Program A stations 
have run. 

C

C

C

C

Содержание ST2-RF

Страница 1: ...ware InDesign CS3 colors additional instructions Font sizes cannot be smaller than 7 pt color non printing PMS 280 PMS color non printing PMS Registration CMYK Printers are responsible for meeting print production requirements Any changes must be approved by the client and Fluid Studio printed piece must meet designated specifications on this form dimensions flat w 13 76 h 5 7 finished w 6 88 d 0 ...

Страница 2: ...nywhere to create or change watering programs Remote Control Capabilities Not included on all models This timer can be controlled by the included remote control device via a radio frequency RF receiver and antennae both of which are built into the timer The remote control device allows you to turn stations on and off on the spot and to perform programming tasks from anywhere within range The 433 m...

Страница 3: ...ttery compartment Replace the battery compartment door Slide the docking port back onto the main controller unit The display will show LOW BATTERY when it is time to replace the batteries NOTE Batteries alone will not operate the valves in your sprinkling system The transformer must be plugged in and have power to oper ate your system normally Reset the Timer If this is the first time the sprinkle...

Страница 4: ... flashes Press the or buttons to select the desired interval select between every 1 day and every 32 days An interval of 2 means it will water every other day You can deactivate the INTERVAL mode by pressing the CLEAR button or by selecting another watering day mode The water drop will disappear Set the Timer to Automatically Run Your Programs Turn the selection dial to AUTO The timer will be cont...

Страница 5: ...Water Budgeting is a quick way to adjust your set durations 10 to 200 based on seasonal requirements Turn the selection dial to BUDGETING LANGUAGE Either press the button to increase the watering times or press the button to decrease the times in increments of 10 percent A setting of 100 will not change the set durations a setting of 200 will increase a 10 minute duration to 20 minutes and a setti...

Страница 6: ... watering from the current station to the next station in the cycle This can be done during scheduled manual or remote actuated watering Section 4 Using the Remote Control Device NOTE The timer will accept commands from the remote control device only when the selection dial is turned to AUTO or OFF If the selection dial is turned to any other setting commands from the Remote Control Device will be...

Страница 7: ...g tools on hand Phillips screwdriver Wire strippers Installing the Sprinkler Timer in Five Easy Steps 1 Select a Location Select a location with the following criteria Near an electrical outlet Avoid using an outlet controlled by a switch In a dry indoor location where operating temperatures are not below 32 or above 122 Fahrenheit below 0 degrees or above 50 degrees Celsius Not in direct sunlight...

Страница 8: ...e against the wall aligning the two holes in the sleeve with the two drilled holes Secure the sleeve to the wall by screwing a No 8 screw included through each of the two holes Slide the remote control device into the sleeve Section 7 Diagnostics Circuit Breaker Smart Scan Diagnostic Fault Sensing A diagnostic fault sensor will automatically scan for the presence of a faulty solenoid or wiring sho...

Страница 9: ...es Front Strip Front North Back North Front Location Spray Heads Spray Heads Gear Drive Shrub Head Sprinkler Grass Grass Grass Shrubs and Flowers Plants Determine a Watering Plan Your timer has two programs Program A and Program B The dual program capability allows you to assign certain water ing stations to Program A and others to Program B There are various reasons why you would want to do so Fo...

Страница 10: ...ormer Push down timer on docking port until back light turns on Reduce the number of start times for that program Install pressure reducer Check wiring or replace solenoid Section 9 Trouble Shooting Help Before returning this sprinkler timer to the store contact Orbit Technical Service at 1 800 488 6156 1 801 299 5555 Listings Hereby Orbit Irrigation Products Inc declares that this conroller is in...

Страница 11: ...e incluye en todos los modelos El temporizador puede controlarse mediante un control remoto que se activa por medio de una antena y un receptor de radiofrecuencia RF incorporados al temporizador El control remoto le permite encender y apagar las estaciones desde su sitio y configurar la programación desde cualquier lugar siempre dentro del alcance del dispositivo La frecuencia remota de 433 megahe...

Страница 12: ...ora y la fecha Determine un plan de riego Activación de las baterías Deslice el terminal de conexión del temporizador para ac ceder a la puerta del compartimiento de las baterías Deslice la puerta del compartimiento de las baterías en la dirección de la flecha Retire la cinta negra del compartimiento de las baterías Vuelva a colocar la puerta del compartimiento de las baterías Deslice el terminal ...

Страница 13: ...el otro programa Salga de la modalidad para colocar duración del riego girando la esfera de selección Establezca los días de riego Gire la esfera de selección DÍAS DE RIEGO para el programa que desee colocar A o B Establecer los intervalos de riego Presione el botón SIGUIENTE para moverse a través de los días de la semana Mo Lunes Tu Martes We Miércoles Th Jueves Fr Viernes Sa Sábado and Su Doming...

Страница 14: ...mojen cuando vayan a la escuela Siga los siguientes pasos Gire la esfera de selección a DÍA PERÍODO SIN RIEGO Presione el botón RETARDO POR LLUVIA En la esfera aparecerá SIN AUGA INICIO PERÍODO Presione el botón o para establecer el inicio del período en el que no desea que se active el agua Presione el botón INGRESAR En el selector aparece SIN AUGA FIN PERÍODO Presione el botón o para establecer ...

Страница 15: ...NTE para seleccionar el número de estación que desea regar Presione el botón o para seleccionar el número de minutos para regar esa estación desde 1 hasta 120 minutos Presione el botón INGRESAR Para abortar el proceso antes que el riego manual se haya termi nado presione BORRAR De otro modo el temporizador saldrá automáticamente de la modo MANUAL ESTACIÓN despues que la estación elegida se haya ac...

Страница 16: ...os X minutos deseados Para regar más de una estación específica Presione los números de las estaciones que desea regar Por ejemplo 3 7 10 y 6 El temporizador regará en orden de menor a mayor 3 6 7 10 Independientemente del orden en el cual presione las teclas el temporizador las regará en orden ascendiente Presione ON X MIN para regar las estaciones durante los X de minutos deseados Para cancelar ...

Страница 17: ...ndividual de color gris encajando comple tamente el cable pelado en la terminal debajo de cada número Vea la Figura 5 Conecte el cable común a una de las dos terminales de color blanco marcada con la palabra COM NOTA Inserte sólo un cable en cada receptáculo COM Si se necesita más de dos cables en común empalme varios juntos para que sólo un cable atraviese cada una de las dos terminales COM Prote...

Страница 18: ...ilas continuarán activando el LCD Tras unos segundos el temporizador restaurará automáticamente el circuito para comprobar si las condiciones han desaparecido Si así es el interruptor del circuito el interruptor se restaurará a sí mismo Hora de inicio del ciclo Válvula maestra Horas de inicio múltiples Programa A o B Retardo por lluvia Solenoide Temporizador del aspersor Apilamiento Estación Estac...

Страница 19: ...riego de los canteros todos los días y utilizar el Programa B para regar el césped cada segundo o tercer día Su temporizador le permite establecer hasta seis horas de inicio diferentes para los ciclos de riego en el Programa A o en el B No puede establecer una hora de inicio de ciclo para cada estación Las estaciones pueden asignarse bien al Programa A o al B Las estaciones asignadas a un programa...

Страница 20: ...esactiva Síntoma Posible causa del problema Ninguna de las estaciones se activa 1 Solenoide defectuoso 2 Cable roto o no está conectado 3 Vástago de control de flujo hacia abajo cerrando la válvula 4 La programación es incorrecta 1 Válvula defectuosa 2 Partículas de sucio o desechos atascados en la válvula 3 Diafragma de la válvula defectuoso El temporizador no responde Las estaciones continúan ac...

Отзывы: