![Orbit Merret OM 402PWR Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/orbit-merret/om-402pwr/om-402pwr_manual_1648160062.webp)
62
| INSTRUCTIONS FOR USE
OM 402PWR
SETTING
PROFI
6.
6.3.2b
SELECTION OF TYPE OF LIMIT
6.3.2c
SELECTION OF TYPE OF OUTPUT
CHANNE.
SERVIC.
OUTPUT.
LIMITS
AN. OUT.
DATA
DISP.
INPUTS MEMORY
LIM 3
LIM 2
LIM 1
LIM 4
INP. L.1
MOD. L.1
TYP. L.1
LIM. L.1
HYS. L.1
ON L.1
OFF. L.1
PER. L.1
TIM. L.1
HYSTER
DOSING
FROM. .
DEF
MOD. L.1
Selection the type of limit
HYSTER
Limit is in mode “Limit,
hysteresis, delay”
- for this mode the parameters of “
LIM. L.1
” are
set, at which the limit will shall react, “
HYS. L.1
”
the hysteresis range around the limit
(LIM ±1/2 HYS) and time “
TIM. L.1
” determining
the delay of relay switch-on
FROM. .
Frame limit
- for this mode the parameters are set for interval
“
ON. L.1
” the relay switch-on and “
OFF. L.1
” the
relay switch-off
DOSING
Dose limit
(periodic)
- for this mode the parameters are set for
“
PER. L.1
” determining the limit value as well
as its multiples at which the output is active
and “
TIM. L.2
” indicating the time during which
is the output active
Setting is identical for
LIM 1
,
LIM 2
,
LIM 3
and
LIM 4
!
CHANNE.
SERVIC.
OUTPUT.
LIMITS
AN. OUT.
DATA
DISP.
INPUTS MEMORY
LIM 3
LIM 2
LIM 1
LIM 4
INP. L.1
MOD. L.1
TYP. L.1
LIM. L.1
HYS. L.1
ON L.1
OFF. L.1
PER. L.1
TIM. L.1
CLOSE
OPEN
DEF
TYP. L.1
Selection of type of output
CLOSE
Output switches on when
condition is met
OPEN
Output switches off when
condition is met
Setting is identical for
LIM 1
,
LIM 2
,
LIM 3
and
LIM 4
!
Содержание OM 402PWR
Страница 9: ...INSTRUCTIONS FOR USE OM 402PWR 9 3 INSTRUMENT CONECTION ...
Страница 31: ...INSTRUCTIONS FOR USE OM 402PWR 31 5 SETTING LIGHT ...
Страница 45: ...INSTRUCTIONS FOR USE OM 402PWR 45 6 SETTING PROFI ...
Страница 71: ...INSTRUCTIONS FOR USE OM 402PWR 71 6 SETTING PROFI ...
Страница 82: ...82 INSTRUCTIONS FOR USE OM 402PWR NOTE ...
Страница 83: ...INSTRUCTIONS FOR USE OM 402PWR 83 NOTE NOTE ...