INSTRUCTIONS FOR USE
OM 402PID
|
61
6.
SETTING
PROFI
6.2.1c
DIGITAL FILTERS
CHAN. B
CHANNE.
SERVIC.
OUTPUT.
CHAN. A
MIN.MAX
CONTR.
INPUTS
FILTER
FORM. A
SET. A
CON. F.A
MOD. F.A
NO
AVER.
FLOAT.
EXPON.
ROUND.
DEF
LOG. A
PROG.
MOD. F.A
Selection of digital
filters
- at times it is useful for better user projection
of data on display to modify it mathematically
and properly , wherefore the following filters
may be used
NO
Filters are off
AVER.
Measured data average
- arithmetic average from given number
(„
CON. F.A
“) of measured values
- range 2…100
FLOAT.
Selection of floating filter
- floating arithmetic average from given number
(„
CON. F.A
“) of measured data and updates
with each measured value
- range 2…30
EXPON.
Selection of exponential
filter
- integration filter of first prvního grade with time
constant („
CON. F.A
“) measurement
- range 2…100
ROUND
Measured value rounding
- is entered by any number, which
determines the projection step
(e.g: „
CON. F.A
“ = 2,5 > display 0, 2.5, 5,...)
CON. F.A
Setting constants
- this menu item is always displayed after
selection of particular type of filter
-
DEF
= 2
Setting is identical for
CHAN. A
and
CHAN.B
!
40
60
20
80
100
Floating filter
Constant F.A = 5.0
36
36
52
52
68
68
84
84
Arithmetic averange
Constant F.A = 5.0
Exponential filter
Constant F.A = 5.0
40
60
20
80
100
40
60
20
80
100
40
60
20
80
100
36
49
59
67
74
79
83
86
89
75
64
55
42
38
34 31
29
27
5
10
20
15
5
10
20
15
5
10
20
15
5
10
20
15
Input value
t
t
t
t
Содержание OM 402PID
Страница 17: ...INSTRUCTIONS FOR USE OM 402PID 17 SETTING LIGHT 5 ...
Страница 37: ...INSTRUCTIONS FOR USE OM 402PID 37 5 SETTING LIGHT ...
Страница 47: ...INSTRUCTIONS FOR USE OM 402PID 47 6 SETTING PROFI ...
Страница 59: ...INSTRUCTIONS FOR USE OM 402PID 59 6 SETTING PROFI ...
Страница 87: ...INSTRUCTIONS FOR USE OM 402PID 87 6 SETTING PROFI ...
Страница 98: ...98 INSTRUCTIONS FOR USE OM 402PID NOTE ...
Страница 99: ...INSTRUCTIONS FOR USE OM 402PID 99 NOTE ...