14
2.3.2 Measurement
By pressing
MEAS
, the mode changes into
measurement
. The Display waits some
seconds until the conditions for correct measurements are fulfilled. This time depends on
the Decelerometer configuration, on the set threshold and on the mode how the
measurement will be started. As soon as these conditions are met, the measurement
starts and the results are recorded during the time interval set in the mode
menu.
The
values of deceleration, force or pressure are calculated. The measured data are filtered in
accordance with the filter setting. At the end of measurement the maximal values of
deceleration, force or pressure are displayed as well as the serial number of the
measurement.
2.3.3 Printing
By pressing
PRN
, the paper will be advanced. When the key is pressed longer, the data
will be printed in graphics.
Printout
After the graphics is finished, the average values of overall deceleration, force or pressure
will be printed. The beginning and the end of the time interval, in which the average values
have to be calculated, must be entered with
up
or
down
arrow
keys. The interval in which
the deceleration is steady - nearly constant, has to be selected.
Papier eject
or printing
For printing
Push button
start 0.8 s
value 6.0m/s
2
Printing.....
Wait, please
Содержание OC 3010