5. Insert the assembled appliance with its connectors into the adjustable
base guides and ensure that is firmly mounted.
6. Screw the two screws with the rubber washers into the mechanism box
by supporting them on their threaded securing holes.
Tighten the screws until they are securely fixed. In this way, the adjustable
base and the appliance will be correctly flush mounted; and the frame
accessory will protrude from the wall.
7. Fit the frame into its fastening accessory.
FITTING AND REPLACING BATTERIES:
The appliance is powered from two LR03 (AAA) 1.5 V alkaline batteries
(not included). Respect the polarity indicated on the battery housing. These
batteries will last approximately one year. It is recommended to set the
operating mode selector to OFF before replacing the batteries
Deposit used batteries in the corresponding container. Respect the
environment
BATTERY LEVEL INDICATOR
To check battery state, simply press the battery level check button and if
the LED lights up, the batteries have a correct charge level. If the LED does
not light up, replace the batteries.
OPERATING MODES
The operating mode selector will choose the type of action to be performed
by the thermostat (this varies depending on model).
TEK Model
-
ON
mode Switch on The unit works in heating mode until the
selected temperature is reached.
-
OFF
mode. Switch off. The equipment does not switch on.
- Mode . Night-time. The thermostat operates in heating and
adjusts the temperature to 5 ºC less than that marked by the
selector.
TEK SW model
- Mode
. Heating. The unit works in heating mode until the
selected temperature is reached.
- Mode
. Cooling. The unit works in cooling mode until the
selected temperature is reached
-
Mode
. Night-time.
The thermostat operates in heating and
adjusts the temperature to 5 ºC less than that marked by the
selector.
TECHNICAL SPECIFICATIONS:
Power supply:
2 LR03 (AAA)1.5 V alkaline batteries
Breaking power:
5 (1) A /250 Vac
Contact:
switched Ag/Ni 90/10
Battery lifetime:
approximately one year
Type of action:
1B
Regulation range:
from +5 ºC to +30 ºC
Regulated temperature precision:
± 1 ºC
Type of temperature regulation:
ON-OFF with 2 ºC hysteresis
Operating temperature range:
from 0 ºC to +50 ºC
Protection class:
II with correct installation
Protection
type:
IP40 according to EN 60529 and
correctly installed
Contamination situation:
2
DIMENSIONS
01/04.2016
A016.32.54213
5
6
65.6
38.5
50.4
44
18.5
44
SUPPLEMENT
ADJUSTABLE BASE
RUBBER
WASHER
NYLON SPACER
METAL CLAMP
83.4
66
50
ORBIS TECNOLOGÍA ELÉCTRICA, S.A.
Lérida, 61 E–28020 MADRID
Teléfono:+ 34 91 5672277; Fax:+34 91 5714006
E-mail: info@ orbis.es