MODEL
RB
WEIR GATES
INTRODUCTION
This manual describes the recommended procedures for installation, operation, maintenance and
safety precautions for Orbinox RB model weir gates. Please read thoroughly all the instructions in the
manual prior to installation, and contact an Orbinox representative in case of any questions. The
manual makes reference to the “General Arrangement Drawing” (GAD). The GAD is the drawing
that is sent to and approved by the customer prior to the production of the weir gate. Orbinox as-
sumes no responsibility or liability if the slide gate is not installed, operated and maintained in strict
accordance to the procedures described in this manual.
HANDLING AND STORAGE
Standard safety procedures should be followed to prevent personal injury or equipment damage.
Additionally, the following instructions shall be followed during handling and storage to prevent any
damage of the product:
Stems have precision surfaces and should never be used as a mean to lift the slide gate.
Special care shall be taken on any machined surface when lifting the gate.
Equipment shall be stored in a dry, clean and even area on a raised even wood surface
to prevent distortion of the frame. Do not stack slide gates
.
Stems and extensions that are shipped separately shall be supported over their entire
length to prevent any bending or distortion while in storage.