background image

 

ORBINOX reserves the right to change specifications without notice. 

ORBINOX CANADA, ORBINOX USA, ORBINOX SPAIN, ORBINOX UK, ORBINOX FRANCE, ORBINOX GERMANY, ORBINOX INDIA, ORBINOX CHINA 

WWW.ORBINOX.COM 

OBXC 05-2010 

05-2010 Edition 
Revision - 

INSTALLATION, OPERATION AND MAINTENANCE MANUAL 

 

MODEL 

RB

 WEIR GATES 

 

INTRODUCTION 

This  manual  describes  the  recommended  procedures  for  installation,  operation,  maintenance  and 
safety precautions for Orbinox RB model weir gates. Please read thoroughly all the instructions in the 
manual  prior  to  installation,  and  contact  an  Orbinox  representative  in  case  of  any  questions.  The 
manual  makes reference to  the  “General  Arrangement  Drawing”  (GAD). The  GAD  is the  drawing 
that is sent to and approved by the customer prior to the production of the weir gate. Orbinox as-
sumes no responsibility or liability if the slide gate is not installed, operated and maintained in strict 
accordance to the procedures described in this manual.  

HANDLING AND STORAGE 

Standard  safety  procedures  should  be  followed  to  prevent  personal  injury  or  equipment  damage. 
Additionally, the following instructions shall be followed during handling and storage to prevent any 
damage of the product: 

Stems have precision surfaces and should never be used as a mean to lift the slide gate. 

Special care shall be taken on any machined surface when lifting the gate. 

Equipment shall be stored in a dry, clean and even area on a raised even wood surface 
to prevent distortion of the frame. Do not stack slide gates

.

 

Stems  and  extensions  that  are  shipped  separately  shall  be  supported  over  their  entire 
length to prevent any bending or distortion while in storage. 

Содержание RB Weir Gate

Страница 1: ...Installation Operation and Maintenance Manual RB Weir Gate...

Страница 2: ...LATION OPERATION AND MAINTENANCE MANUAL MODEL RB WEIR GATES INDEX Introduction Handling and Storage Installation Weir Gate installation Concrete Wall Mounted Concrete Round Manhole Wall Mounted Wall T...

Страница 3: ...y the customer prior to the production of the weir gate Orbinox as sumes no responsibility or liability if the slide gate is not installed operated and maintained in strict accordance to the procedure...

Страница 4: ...truction sealant shall be used Sikabond Construction Sealant or equivalent 200ml per meter of opening perimeter The following table gives a general description of the required anchor bolt types for th...

Страница 5: ...ncrete construction shall be flat level and plumb and shall be in accordance to ACI 117 06 standard If necessary use non shrink grout in order to meet the specified standard Concrete wall surface shal...

Страница 6: ...ant application Sikabond or equivalent In order to avoid leakage between the frame and the wall construction sealant shall be applied on the frame Remove the weir gate from the wall first remove the n...

Страница 7: ...ll and install the rest of the anchor bolts see Figure 5 CAUTION If the weir gate is not completely in contact with the wall do not over tighten the an chor bolts Over tightening may bend or distort t...

Страница 8: ...ll be used Sikabond Con struction Sealant or equivalent 200ml per meter of opening perimeter For detailed information about the size and quantity of the required bolts or any other specific installati...

Страница 9: ...2 Insert all stem guides from the top of the stem extension when applicable Align stem extension and especially make sure that it is aligned with the vertical axis of the opening see Figure 7 The maxi...

Страница 10: ...A ORBINOX SPAIN ORBINOX UK ORBINOX FRANCE ORBINOX GERMANY ORBINOX INDIA ORBINOX CHINA WWW ORBINOX COM OBXC 05 2010 10 05 2010 Edition Revision INSTALLATION OPERATION AND MAINTENANCE MANUAL MODEL RB WE...

Страница 11: ...tion before cycling the weir gate Manu ally open the gate approximately 5 before the initial electric motor operation Check the motor rotation to assure proper direction of the slide travel according...

Страница 12: ...and in the guides Check the seals and make sure they are not damaged Seals shall be replaced if damaged See section Maintenance Seal Replacement for detailed procedures about seal replacement Seals s...

Страница 13: ...s item 4 UHMWPE guides item 5 and frame Proceed with caution as major components of the gate are no longer se cured Step 3 Remove frame guides item 4 UHMWPE guides item 5 slide item 7 yoke item 6 and...

Страница 14: ...DA ORBINOX USA ORBINOX SPAIN ORBINOX UK ORBINOX FRANCE ORBINOX GERMANY ORBINOX INDIA ORBINOX CHINA WWW ORBINOX COM OBXC 05 2010 14 05 2010 Edition Revision INSTALLATION OPERATION AND MAINTENANCE MANUA...

Страница 15: ...MAINTENANCE SEAL REPLACEMENT 49 X49 TO 80 X80 Step 1 Start from the open position Step 2 Unscrew bolts item 1 with caution as the slide is no longer secured Step 3 Unscrew bolts and nuts items 10 and...

Страница 16: ...ADA ORBINOX USA ORBINOX SPAIN ORBINOX UK ORBINOX FRANCE ORBINOX GERMANY ORBINOX INDIA ORBINOX CHINA WWW ORBINOX COM OBXC 05 2010 16 05 2010 Edition Revision INSTALLATION OPERATION AND MAINTENANCE MANU...

Страница 17: ...install the weir gate clean the wall and apply a new layer of construction sealant Loose anchor bolts Tighten anchor bolts Incorrect anchor bolts Check the General Arrangement Drawing and make sure th...