INSTALLATION: CONCRETE WALL MOUNTED
continued
Step 3: Construction sealant application (Sikabond or equivalent)
In order to avoid leakage between the frame and the wall, construction sealant shall be applied on
the frame:
Remove the weir gate from the wall (first remove the nuts of the anchor bolts).
Apply construction sealant all around the perimeter of the frame. Sikabond (200 ml/m) or
equivalent construction sealant shall be used (See Figure 3 and Figure 4). Be sure not to get
sealant on the gate‟s seals, guides, and/or stem, as this may cause leakage or damage.
Re-install the weir gate on the wall and tighten both anchor bolts.