When the programming mode is working,
●
On this display, We can see the day, the temperature according to the set mode (Comfort, Economy, Anti-
frost) and the squares flash showing the current time if the set mode is the Comfort or Economy Mode.
●
This display shows Day 1, Comfort mode temperature 24ºC and the square is flashing at the sun symbol
between 0:00 and 1:00, which means it runs on Comfort mode between 0:00 and 1:00 on Monday.
●
On this mode, we can set Comfort or Economy temperature according to our requirements by pressing
or –.
Fig.29
Temperature Compensation:
Due to the characteristics of the appliance, the temperature is measured on the lower part of the
radiator, being perfectly adjusted in relation to the Comfort temperature selected by the user.
However, it is also possible to set the “Temperature Compensation” manually.
Room temperature recorded - Comfort temperature indicated = Value…
For example:
22ºC in a room temperature measured with the thermometer when the Comfort temperature required
on the thermostat (indicated) is 20ºC.
The temperature compensation value is 22 – 20 = +2ºC
The user must enter +2ºC on the temperature compensation menu.
Step 1 : Turn the thermostat to the Off position by pressing the button .
Step 2: By pressing button
M
and holding for for 5 seconds, we will enter this menu where the display
shows 0.0