Servicing Power Supplies (CRU)
This section describes how to service power supplies. Power supplies are customer-replaceable
units (CRUs) that do not require you to power off the server. For more information about CRUs,
see
“Illustrated Parts Breakdown” on page 20
“Customer-Replaceable Units” on page 21
The power supplies are located at the back of the server. See the following procedures:
■
“Power Supply Overview” on page 93
■
“Remove a Power Supply” on page 94
■
“Install a Power Supply” on page 96
Power Supply Overview
The server's redundant power supplies support concurrent maintenance, which enables you to
remove and replace a power supply without shutting down the server, provided that the other
power supply is online and working.
The server supports model A266 (1200 watt) power supplies. The A266 power supply unit
(PSU) provides conversion from the AC lines to the system, accepting ranges from 100-240
volts AC (VAC). These PSUs are designed to be hot-pluggable, and in most cases will provide
fully redundant “1+1” power, allowing the system to suffer the loss of a PSU or an AC feed
with no loss to system availability.
In maximally configured systems, it is possible that the worst-case power consumption of the
system could exceed the capacity of a single PSU. The PSUs provide an over-subscription
mode, which allows the system to operate with fault-tolerance even with modest excursions
beyond the rated capacity of a single PSU. This over-subscription support is accomplished
using hardware signaling between the PSU and motherboard circuitry, which can force the
system to throttle processor (CPU) and memory power in the event that a PSU is lost. The
resulting power savings will be enough to allow the system to continue to run (in a lower-
performance state) until the power problem is resolved.
The following status indicators (LEDs) are lit when a power supply fault is detected:
Servicing Power Supplies (CRU)
93
Содержание X7-2L
Страница 1: ...Oracle Server X7 2L Service Manual Part No E72474 02 October 2017 ...
Страница 2: ......
Страница 12: ...12 Oracle Server X7 2L Service Manual October 2017 ...
Страница 14: ...14 Oracle Server X7 2L Service Manual October 2017 ...
Страница 48: ...48 Oracle Server X7 2L Service Manual October 2017 ...
Страница 66: ...66 Oracle Server X7 2L Service Manual October 2017 ...
Страница 84: ...84 Oracle Server X7 2L Service Manual October 2017 ...
Страница 92: ...92 Oracle Server X7 2L Service Manual October 2017 ...
Страница 110: ...110 Oracle Server X7 2L Service Manual October 2017 ...
Страница 130: ...130 Oracle Server X7 2L Service Manual October 2017 ...
Страница 138: ...138 Oracle Server X7 2L Service Manual October 2017 ...
Страница 142: ...142 Oracle Server X7 2L Service Manual October 2017 ...
Страница 156: ...156 Oracle Server X7 2L Service Manual October 2017 ...
Страница 164: ...164 Oracle Server X7 2L Service Manual October 2017 ...
Страница 172: ...172 Oracle Server X7 2L Service Manual October 2017 ...
Страница 178: ...178 Oracle Server X7 2L Service Manual October 2017 ...
Страница 218: ...218 Oracle Server X7 2L Service Manual October 2017 ...
Страница 224: ...USB Ports Reconnect Power and Data Cables on page 216 224 Oracle Server X7 2L Service Manual October 2017 ...
Страница 254: ...254 Oracle Server X7 2L Service Manual October 2017 ...