BIOS POST Error Message
Error Type
Resolution
Password check failed
Password
check error
■
Press F1 to continue.
■
Check the SP event log in ILOM for more details.
Note –
This type of error indicates a password
entered does not match the password specified in
the BIOS Setup utility. This condition might
occur for both Supervisor and User password
verification.
Keyboard/Interface Error
Keyboard
controller error
■
Press F1 to continue.
■
Check the SP event log in ILOM for more details.
Note –
This type of error indicates a Keyboard
Controller failure. This error might indicate a
problem with the system hardware.
S.M.A.R.T. error on the drive
S.M.A.R.T.
device error
■
Press F1 to continue.
■
Check the SP event log in ILOM for more details.
Note –
S.M.A.R.T. failure messages might
indicate to replace the storage device.
BIOS POST Memory Testing Sequence
The BIOS POST memory testing sequence is performed as follows:
1. The first megabyte of DRAM is tested by the BIOS before the BIOS code is shadowed (that
is, copied from ROM to DRAM).
2. After executing out of DRAM, the BIOS performs a simple memory test (where a write/read
of every location with the pattern 55aa55aa is performed).
Note –
The simple memory test is performed only if Quick Boot is not enabled from the Boot
Settings Configuration screen. Enabling Quick Boot causes the BIOS to skip the memory
test.
3. The BIOS polls the memory controllers for both correctable and non-correctable memory
errors and logs those errors into the SP.
4. The message BMC Responding appears at the end of the POST.
BIOS POST Memory Testing Sequence
87