If you are
not
installing a new heatsink, use the alcohol pads to remove any residual thermal
compound from the bottom of the heatsink.
Apply thermal compound to the top of the CPU.
For best application, use the
entire
contents of the pre-filled syringe and apply the compound in
a star (asterisk) pattern.
Carefully position the heatsink over the CPU, aligning it with the mounting posts.
After the heatsink contacts the CPU, minimize the movement .
Caution –
If the heatsink is moved too much during its installation, the layer of thermal
compound might become uneven, leading to component damage.
To secure the heatsink to the motherboard, alternately tighten the four screws.
Alternately turn each screw one full turn until all the screws are tightened fully.
Install the air duct. See
“How to Install the Air Duct”on page 53
.
Prepare the server for operation. See
“How to Prepare for Operation”on page 26
.
▼
How to Add a New CPU and Heatsink Assembly
Use this procedure if you are
adding
a CPU to your server.
See:
“Locations of Internal Server Components” on page 30
Prepare the server for service. See
“How to Prepare for Service”on page 21
.
Remove the air duct. See
“How to Remove the Air Duct”on page 53
.
8
9
10
11
12
13
Before You Begin
1
2
Removing, Installing, and Adding a CPU and Heatsink (FRU)
Sun Fire X2270 M2 Server Service Manual • January, 2012, –12
70