Preparing the Site
7
The following table provides descriptions of the CXP signals.
Related Information
■
“InfiniBand Cable Types” on page 12
■
“Connecting InfiniBand Cables” on page 108
Routing Service Cables
These topics describe cable routing.
■
“Power Cord Requirements” on page 8
19
GND
40
GND
61
GND
82
GND
20
SCL
41
VCC3.3-Tx
62
PRSNT
83
VCC3.3-Rx
21
SDA
42
VCC12-Tx
63
Int_L/Reset
_L
84
VCC12-Rx
Signal
Description
GND
Ground for both signal and power return
VCC3.3-Tx
3.3V standby power from the power supplies
VCC3.3-Rx
3.3V standby power return
VCC12-Tx
12V power for cable export and future enhancements
VCC12-Rx
12V power return
TX
portdiff
Differential InfiniBand transmit signal, where:
•
port
– 0 to 11
•
diff
– n or p for negative or positive
RX
portdiff
Differential InfiniBand receive signal, where:
•
port
– 0 to 11
•
diff
– n or p for negative or positive
SCL
I
2
C clock
SDA
I
2
C data I/O
PRSNT
Connection present
Int_L/Reset_L
Reset line
Pin
Signal
Pin
Signal
Pin
Signal
Pin
Signal