To Verify Proper Installation (Oracle x86)
26
StorageTek 8 Gb FC PCIe HBA From QLogic Installation Guide • March 2015
4.
Use the Arrow key to highlight Scan Fibre Devices and press Enter.
In the example that follows, a storage JBOD has six targets attached to one port of a dual port
HBA.
The following QLogic
Fast!
UTIL menu is displayed.
QLogic Fast!UTIL
Scan Fibre Channel Loop
ID Vendor Product Rev Port Name Port ID
0 SEAGATE ST336752FSUN36G 0205 21000004CF64C8E0 0000CC
1 SEAGATE ST336752FSUN36G 0205 21000004CF6493D0 0000CB
2 SEAGATE ST336752FSUN36G 0205 21000004CF6428C4 0000CA
3 SEAGATE ST336752FSUN36G 0205 21000004CF64C5B2 0000C9
4 SEAGATE ST336752FSUN36G 0205 21000004CF6096F0 0000C7
5 SEAGATE ST336752FSUN36G 0205 21000004CF648010 0000C6
6 SUN StorEdge 3510F D1046 215000C0FF00225B 0000CD
7 No device present
8 No device present
9 No device present
10 No device present
11 No device present
12 No device present
13 No device present
14 No device present
15 No device present
5.
To exit the QLogic
Fast!
UTIL, press the Escape key, highlight Exit Fast!UTIL, and
press Enter.
The following QLogic
Fast!
UTIL menu is displayed.
QLogic Fast!UTIL
Selected Adapter
----------------------------------------------------------
Adapter Type I/O Address Slot Bus Device Function
QLE2562 9400 01 02 01 1
----------------------------------------------------------
Fast!UTIL Options
Configuration Settings
Scan Fibre Devices
Fibre Disk Utility
Loopback Data Test
Select Host Adapter
Exit Fast!UTIL