Environmental Requirements
■
Shock and vibration
■
Acoustic
TABLE 1
Temperature, Humidity, and Elevation Specifications
Operating
Nonoperating
Description
Metric
U.S.
Metric
U.S.
Notes
Temperature
(maximum)
5° to 35° C
at 900m
41° to 95° F at 0
to 3000 ft
-40° to 65° C
at 900m
-40° to 149° F
at 0 to 3000 ft
Decrease in maximum
temperature: above 3000 ft.
(900m), 1.8°F/1000 ft (1°
C/300m)
Relative
humidity
10 to 90%
at 27° C
10 to 90%
at 81° F
Up to 93%
at 38° C
Up to 93%
at 100° F
Maximum wet bulb,
noncondensing
Altitude
0 to 3000 m
at 40° C
0 to 9840 ft at
95° F
Up to 12,000 m
Up to 40,000 ft
In China markets, regulations
may limit installations to a
maximum operating altitude of
2000m.
TABLE 2
Shock and Vibration Specifications
Description
Operating
Notes
Shock
3 G, 11 ms
Half-sine
Vibration (vertical)
0.15 G
5 to 500 HZ swept-sine
Vibration (horizontal)
0.10 G
TABLE 3
Acoustic Specifications
Description
Operating at Idle
Operating at Peak Power
Sound Power Level - LwAd
(1 B = 10 dB)
7.8 B
9.4 B
Sound Pressure Level - LpAm
(energy average of 4 bystander positions)
61.8 dBA
79.7 dBA
Related Information
■
SPARC T7-4 Server Safety and Compliance Guide
■
“Physical Specifications” on page 17
■
“Electrical Specifications” on page 18
■
“Airflow Precautions” on page 21
20
SPARC T7-4 Server Installation Guide • March 2017
Содержание SPARC T7-4
Страница 1: ...SPARC T7 4 Server Installation Guide Part No E54993 04 March 2017 ...
Страница 2: ......
Страница 8: ...8 SPARC T7 4 Server Installation Guide March 2017 ...
Страница 10: ...10 SPARC T7 4 Server Installation Guide March 2017 ...
Страница 22: ...22 SPARC T7 4 Server Installation Guide March 2017 ...
Страница 28: ...28 SPARC T7 4 Server Installation Guide March 2017 ...
Страница 64: ...64 SPARC T7 4 Server Installation Guide March 2017 ...
Страница 86: ...86 SPARC T7 4 Server Installation Guide March 2017 ...