Install the Drive Backplane
Note -
The SAS cable connectors on the motherboard are labeled top and bottom. Plug the
both SAS cables into the drive backplane, then install the top SAS cable into the motherboard
connector labeled top. Install the other SAS cable into the bottom connector.
5.
Replace the System Remind button assembly (air divider).
6.
Replace all memory risers you removed.
See
“Install a Memory Riser” on page 106
.
7.
Replace the DVD drive.
See
“Install a DVD Drive” on page 114
8.
Replace all drives and filler panels.
See
.
9.
Return the server to operation.
See
“Returning the Server to Operation” on page 171
162
SPARC T7-2 Server Service Manual • July 2019
Содержание SPARC T7-2
Страница 1: ...SPARC T7 2 Server Service Manual Part No E54987 10 July 2019 ...
Страница 2: ......
Страница 10: ...10 SPARC T7 2 Server Service Manual July 2019 ...
Страница 12: ...12 SPARC T7 2 Server Service Manual July 2019 ...
Страница 28: ...28 SPARC T7 2 Server Service Manual July 2019 ...
Страница 64: ...64 SPARC T7 2 Server Service Manual July 2019 ...
Страница 84: ...84 SPARC T7 2 Server Service Manual July 2019 ...
Страница 112: ...112 SPARC T7 2 Server Service Manual July 2019 ...
Страница 116: ...116 SPARC T7 2 Server Service Manual July 2019 ...
Страница 120: ...120 SPARC T7 2 Server Service Manual July 2019 ...
Страница 134: ...134 SPARC T7 2 Server Service Manual July 2019 ...
Страница 146: ...146 SPARC T7 2 Server Service Manual July 2019 ...
Страница 164: ...164 SPARC T7 2 Server Service Manual July 2019 ...
Страница 170: ...170 SPARC T7 2 Server Service Manual July 2019 ...
Страница 176: ...176 SPARC T7 2 Server Service Manual July 2019 ...
Страница 182: ...182 SPARC T7 2 Server Service Manual July 2019 ...
Страница 188: ...188 SPARC T7 2 Server Service Manual July 2019 ...