Servicing Processor Modules
59
Servicing Processor Modules
The SPARC T5-8 server supports two configurations:
■
Fully-populated — four processor modules
■
Half-populated — two processor modules and two processor filler modules
Processor modules and processor filler modules are cold-service components that can be
replaced only after you remove all power from the system. For the location of the processor
“Front Panel Components (Service)” on page 14
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause server components to fail.
These topics describe how to service the processor modules:
■
“Server Upgrade Process” on page 59
■
“Processor Module LEDs” on page 61
■
“Determine Which Processor Module Is Faulty” on page 62
■
“Remove a Processor Module or Processor Filler Module” on page 63
■
“Install a Processor Module or Processor Filler Module” on page 67
■
“Verify the Processor Module” on page 70
Related Information
■
■
“Detecting and Managing Faults”
■
■
“Component Service Task Reference” on page 23
■
“Returning the Server to Operation”
Server Upgrade Process
The SPARC T5-8 server supports two configurations:
Содержание SPARC T5-8
Страница 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Страница 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Страница 47: ...View Log Files Oracle ILOM Detecting and Managing Faults 47 View Log Files Oracle Solaris on page 46 ...
Страница 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Страница 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Страница 104: ...Install a Storage Backplane 104 SPARC T5 8 Server Service Manual November 2015 2 Lower the storage backplane into place ...
Страница 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Страница 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Страница 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Страница 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Страница 160: ...Remove a PCIe Card 160 SPARC T5 8 Server Service Manual November 2015 3 Unlatch and open the top cover of the carrier ...
Страница 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Страница 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Страница 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Страница 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Страница 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...