Verify the Processor Module
70
SPARC T5-8 Server Service Manual • November 2015
Related Information
■
■
“Verify the Processor Module” on page 70
■
“Server Upgrade Process” on page 59
Verify the Processor Module
1.
Ensure that you have completed the following:
■
Applied power to the server.
See
“Connect the Power Cords” on page 191
■
Started the system.
See
“Power On the Server (Oracle ILOM)” on page 192
2.
If you replaced a faulty PM, log in to the
fmadm
shell, and use the
fmadm
faulty
command to determine if a fault on the PM is shown:
->
start /SP/faultmgmt/shell
Do you want to start the /SP/faultmgmt/shell (y/n)?
y
faultmgmtsp>
fmadm faulty
a.
If the output shows the replacement PM as enabled, go to
b.
If the output shows the replacement PM as disabled, go to
to clear the fault from the server.
3.
Verify that the OK LED is lit on the PM and that the Fault LED is not lit.
See
“Processor Module LEDs” on page 61
4.
Verify that the front and rear Service Required LEDs are not lit.
See
“Front Panel Controls and LEDs” on page 31
and
.
5.
Perform one of the following tasks based on your verification results:
■
“Diagnostics Process” on page 25
.
■
If no fault was detected, then the processor module was installed
successfully.
Содержание SPARC T5-8
Страница 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Страница 2: ......
Страница 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Страница 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Страница 47: ...View Log Files Oracle ILOM Detecting and Managing Faults 47 View Log Files Oracle Solaris on page 46 ...
Страница 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Страница 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Страница 104: ...Install a Storage Backplane 104 SPARC T5 8 Server Service Manual November 2015 2 Lower the storage backplane into place ...
Страница 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Страница 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Страница 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Страница 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Страница 160: ...Remove a PCIe Card 160 SPARC T5 8 Server Service Manual November 2015 3 Unlatch and open the top cover of the carrier ...
Страница 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Страница 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Страница 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Страница 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Страница 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...