Determine Which DIMM Is Faulty
Determine Which DIMM Is Faulty
This procedure describes how to use the DIMM LEDs on the motherboard to pinpoint the
physical location of a faulty DIMM.
Note -
You can also obtain the location of the faulty DIMM using the
fmadm faulty
command.
This command displays the FRU name. See
and
Caution -
Components inside the chassis might be hot. Use caution when servicing components
inside the chassis.
1.
Check the front panel Fault LED.
“Interpreting LEDs” on page 23
When a faulty DIMM is detected, the front panel Fault LED is illuminated. Before opening the
server module to check the DIMM Fault LEDs, verify that the Fault LED is lit.
■
If the Fault LED is not lit, and you suspect there is a problem, see
.
■
If the Fault LED is lit, go to the next step.
2.
(If needed) Prepare for service.
“Preparing for Service” on page 39
.
3.
Press the Fault Remind button on the motherboard.
While the Remind button is pressed, an LED next to the faulty DIMM lights, enabling you to
Tip -
The DIMM Fault LEDs are small and difficult to identify when they are not lit. If you do
not see any illuminated LEDs in the area of the DIMM LEDs, use the
fmadm faulty
command
and the DIMM layout table to locate the faulty DIMM.
4.
Remove the faulty DIMM.
Related Information
■
Servicing DIMMs
67
Содержание SPARC T5-1B
Страница 1: ...SPARC T5 1B Server Module Service Manual Part No E35203 07 February 2019 ...
Страница 2: ......
Страница 10: ...10 SPARC T5 1B Server Module Service Manual February 2019 ...
Страница 16: ...16 SPARC T5 1B Server Module Service Manual February 2019 ...
Страница 52: ...Remove the Cover Replace the Cover on page 99 52 SPARC T5 1B Server Module Service Manual February 2019 ...
Страница 104: ...104 SPARC T5 1B Server Module Service Manual February 2019 ...
Страница 110: ...110 SPARC T5 1B Server Module Service Manual February 2019 ...