![Oracle SPARC Enterprise M4000 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/oracle/sparc-enterprise-m4000/sparc-enterprise-m4000_installation-manual_1646122069.webp)
Appendix B
Fault Isolation
B-11
B.3.2
Using the
prtdiag
Command
The
prtdiag
command displays configuration and diagnostic information. The
diagnostic information identifies any failed component.
The
prtdiag
command is located in the
/usr/platform/
platform-name
/sbin/
directory.
Note –
The
prtdiag
command might indicate a slot number different than that
identified elsewhere in this document. This is normal.
B.3.2.1
Options
TABLE B-4
describes options for the
prtdiag
command and how those options can
help troubleshooting.
TABLE B-4
Options for
prtdiag
Option
Description
How It Can Help
No option
Lists components.
Identifies CPU timing and PCI cards installed.
-v
Verbose mode. Displays the
time of the most recent AC
power failure and the most
recent hardware fatal error
information.
Provides the same information as no option. Additionally
lists fan status, temperatures, ASIC, and PROM revisions.