3-8
SPARC Enterprise M4000/M5000 Servers Installation Guide • February 2012
FIGURE 3-3
Operator Panel Mode Switch
For more details on the operator panel see
Section A.3, “Operator Panel
Overview” on page A-9
.
4. Turn on the input power.
Note –
Wait at least 30 seconds before turning on the system power that you turned
off, by pulling out the power cord or using the circuit breakers on the distribution
panel.
Refer to the manual that shipped with the input power source for instructions.
5. Watch the administration console for error messages as the XSCF Unit powers
on.
See
Appendix B
,
Fault Isolation
for fault information.
6. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.
7. When the
login
prompt appears, enter default for the login name:
Note –
Step 8 must be performed within a minute of Step 7 or the login certification
will time out.
8. Set the mode switch on the operator panel to the Locked position.
9. Press the RETURN key.
Wait five seconds before continuing to Step 10.
10. Set the mode switch on the operator panel to the Service position.
11. Press the RETURN key.
login:
default