1.6 Connecting the Cables
Connect cables to the Oracle Exalytics In-Memory Machine as follows:
1.
Connect an Ethernet cable to the Gigabit Ethernet (
NET0
) connectors as needed for
operating system support. See the part 8 in
.
2.
(Optional) If you want to interact with the system console directly, connect any
external devices, such as a mouse and keyboard, to the server's USB connectors,
or a monitor to the DB-15 video connector. See parts 9 and 13 in
3.
If you plan to configure network IP address for Oracle Integrated Lights Out
Manager (ILOM), connect an Ethernet cable to the Ethernet port labeled
SER MGT
.
See the part 12 in
4.
If you plan to access the ILOM command-line interface (CLI) using the serial
management port, connect a serial null modem cable to the RJ-45 serial port
labeled
SER MGT
1.7 Connecting the Power Cords
Connect the power cords to the Oracle Exalytics In-Memory Machine as follows:
1.
Connect two grounded server power cords to grounded electrical outlets.
2.
Connect the two server power cords to the AC connectors on the back panel of the
server.
When power is connected, the server boots into standby power mode. In standby
power mode, the SP OK/Fault LED flashes, but the main Power/OK LED remains off.
After a few minutes, the main Power/OK LED slowly flashes the standby pattern,
indicating the service processor (SP) is working. Note that the server is not initialized
or powered on yet.
Figure 1-5 Front Panel Controls
Figure Legend
1 - Power/OK LED
2 - Power button
3 - SP OK/Fault LED
Chapter 1
Connecting the Cables