Verify Operation of Slide-Rails and CMA
the storage server into the rack. As you push the storage server into the
rack, verify that the CMA retracts without binding.
Note -
To pull the green release tab, place your finger in the center of the tab, not on the end,
and apply pressure as you pull the tab toward the front of the storage server.
b.
Continue pushing the storage server into the rack until the slide-rail locks
(on the front of the storage server) engage the slide-rail assemblies.
You will hear an audible click when the storage server is in the normal rack position.
6.
Adjust the cable straps and the CMA, as required.
Related Information
■
“Install the Cable Management Arm” on page 40
54
Oracle Exadata Storage Server X5-2 Extreme Flash Installation Guide • July 2018