To Verify That the Label of a Logical Drive Is Valid
valid Oracle Solaris label, and therefore can be recognized by the OS. Sometimes, logical drives
need to be relabeled using the
format
command (forSPARC systems) or the
fdisk
command
(for x86 systems) in order to be recognized.
To Verify That the Label of a Logical Drive Is Valid
Note -
For your reference, this section provides an example procedure for a SPARC system that
runs the Oracle Solaris OS. For an x86 system that runs the supported OS, you would use the
fdisk
command for that OS to verify the label of a disk. For more information about labeling
disks using the
fdisk
command, see the documentation for your OS.
1.
Become a root user and issue the
format
command.
#
format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c1t0d0 <DEFAULT cyl 24611 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@a/pci17c2,10@4/sd@0,0
1. c1t1d0 <DEFAULT cyl 24810 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@a/pci17c2,10@4/sd@1,0
2. c3t8d0 <DEFAULT cyl 24619 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@b/pci1000,10c0@1,1/sd@8,0
3. c3t9d0 <DEFAULT cyl 24619 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@b/pci1000,10c0@1,1/sd@9,0
4. c3t10d0 <DEFAULT cyl 24619 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@b/pci1000,10c0@1,1/sd@a,0
5. c3t11d0 <DEFAULT cyl 24619 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@b/pci1000,10c0@1,1/sd@b,0
6. c3t12d0 <DEFAULT cyl 24619 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@b/pci1000,10c0@1,1/sd@c,0
7. c3t13d0 <DEFAULT cyl 24619 alt 2 hd 27 sec 107>
/pci@0,0/pci1022,7450@b/pci1000,10c0@1,1/sd@d,0
Specify disk (enter its number):
2.
When prompted, type the number of the disk drive that is attached to the HBA
card you just installed, and press Enter.
The Format menu is displayed.
#
format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
42
Oracle Storage 12 Gb SAS PCIe RAID HBA, Internal: 16 Port and 2 GB Memory Installation Guide For HBA Model
7116970 • September 2017
Содержание 7116970
Страница 2: ......