background image

 

Hold 

MODE

 button longer than 2s, will activate mode selection process. 

Current can be changed only when mode selection routine is activated. 

Hold 

MODE

  button  longer  than  6s,  will  activate  li-ion  battery  type 

programming  mode:  press  MODE  button  to  toggle  between  LiFeO4, 

Li-3.7 and Li-3.8. 

Hold 

CURRENT

 button longer than 2s ( Li-ion battery must need to be 

mounted in battery slot) , will activate USB output on/off process. Short 

press to toggle between USB output on/off state.     

 

5. 

Operation Modes and Display 

5.1 Charger Operation Modes: 

 

Charge  Mode:  The  rechargeable  battery  is  charged  up  to  its 

maximum capacity. Accumulated charging capacity is displayed 

at mAH display mode. 

 

Discharge Mode: It is used to reduce the memory effect.  The 

rechargeable battery is discharged to a preset battery voltage 

(0.9v).  Once  discharge  is  finished,  total  accumulated 

discharging  capacity  is  displayed  at  mAH  display  mode, 

showing  how  much  energy  is  discharged  from  the  battery, 

which  is  always  referring  to  the  accumulated  discharging 

capacity.  No  trickle  charge  current  will  be  applied  after 

discharge cycle is finished.   

 

Refresh  Mode:  The  rechargeable  battery  is  charged  and 

discharged repeatedly to optimize to its maximum capacity. Old 

rechargeable batteries or rechargeable batteries that have not 

been  used  for  a  long  period  of  time  can  be  restored  to  their 

rated  capacity.  Depends  on  the  selected  charge  current  and 

battery  impedance,  it  can  take  tens  hours  or  even  days  time 

before  complete.  Refresh  mode  will  make  3  complete 

discharge-charge  working  cycles  before  complete.  After 

discharge cycle is complete, the total discharged capacity will 

be  displayed  in  mAH  display  mode.  When  its  current  working 

cycle is in charging state, the mAH display is always referring to 

last discharging cycle for its charged capacity..   

 

Test  mode:    Checks  the  present  capacity  of  a  rechargeable 

battery.  The  maximum  capacity  is  determined  by  discharging 

the  rechargeable  battery  after  it  was  fully  charged.  If  the 

maximum capacity is much lower than the rated capacity then it 

may reach the end of its lifetime. 

 

Impedance  Test  mode:  The  charger  will  analyze  the  dynamic 

internal battery resistance by applying  a load current and this 

current reading is referred to the voltage drop detected on the 

battery.  Within  10s,  the  tested  battery  resistance  will  be 

displayed in the unit of milliohm. For good quality batteries, the 

internal resistance is very low: in the range of 20 ~ 80 milliohms. 

If  battery  internal  resistance  is  over  500milliohms,  then  these 

batteries are not good for supplying power to high current loads, 

such  as  digital  camera  etc.  But  they  can  still  be  used  for  low 

energy  loads,  such  as  clock,  remote  controllers  etc.    Always 

use  batteries  with  close  internal  resistance  range  when  they 

are used in serial to achieve maximum battery life. Alkaline and 

any other 1.5v batteries can be tested on this charger as well. If 

a completely empty battery is to be tested, it is not possible to 

give  any  correct  reading.  Please  be  noted  that  since  the 

internal  battery  resistance  can  be  very  small,  and  contact 

resistance can be a major influence factor, thus same battery 

tested  in  different  slot  or  even  at  the  same  slot  with  different 

contact  condition,  the  reading  can  be  varied  for  10% to  20%. 

This is normal. 

When  a  high  impedance  battery(  e.g.  Over  2500milli  ohm)  is 

loaded  onto  the  charger,  due  to  its  high  internal  impedance, 

real  displayed  charging  current  can  be  much  less  than  your 

pre-selected charging current. When this happened, it doesn’t 

mean  the  charger  is  defective.  Eventually  it  needs  longer 

charging time until fully charged. 

5.2  USB OUTPUT MODE 

Press  “CURRENT”  button  to  turn  on/off  USB  output.  When  USB 

output  is  at  ON  state,  press  “CURRENT”  button  to  toggle  display 

between current and AH.   

5.3  Display 

 

Charge/Discharge Current: instantaneous current is displayed. 

 

Time  Elapsed:  The  charging/discharging  time  of  the  last  cycle  is 

displayed. 

 

Accumulated  Capacity:  The  accumulated  battery  capacity  is 

displayed  in  mAh.  For  discharge  mode,  it  is  referring  to  the 

accumulated  energy  discharged  from  that  battery.  For  refresh 

mode, previous charging capacity is displayed even when current 

working stage is at discharge cycle. 

 

Battery Voltage: The instantaneous battery voltage is displayed. 

 

At  IMPEDANCE  TEST  mode,  it  shows  the  internal  battery 

resistance in mili- ohm(0.001R). 

 

Full:  After  the  rechargeable  battery  is  fully  charged  in  any  of  the 

operation  modes,  trickle  charging  will  be  started  automatically. 

Trickle  charging  prevents  the  rechargeable  batteries  from  being 

overcharged and compensates for self-discharging of the batteries 

 

6. 

Maintenance 

Содержание bt-c100

Страница 1: ...AH data can be much higher than battery capacity this is due to part of charging current is bypassed to USB output circuit Please be aware this and it is not charger wrong for its displayed mAh data not matching battery rating capacity Charger will automatically reduce 500mA working current when over heat is sensed over 80C during charging or discharging state It will resume full working current u...

Страница 2: ...amage through leaking Leaking or damaged batteries might cause acid burns when in contact with skin therefore use suitable protective gloves to handle corrupted batteries Batteries must be kept out of reach of children Do not leave the battery lying around as there is risk that children or pets swallow it When charging current more than 1 0A is selected for charging charger should not be left unat...

Страница 3: ...eading is referred to the voltage drop detected on the battery Within 10s the tested battery resistance will be displayed in the unit of milliohm For good quality batteries the internal resistance is very low in the range of 20 80 milliohms If battery internal resistance is over 500milliohms then these batteries are not good for supplying power to high current loads such as digital camera etc But ...

Страница 4: ...rgeable batteries Disposing used batteries in the household waste is prohibited Batteries rechargeable batteries containing hazardous substances are marked with the crossed out wheeled bin The symbol indicates that the product is forbidden to be disposed via the domestic refuse The chemical symbols for the respective hazardous substances are Cd Cadmium Hg Mercury Pb Lead You can return used batter...