OTS Series Command Line Interface User Guide
Page 70 of 95
configure snmp trap linecard <shelf/slot> fault disable
This command disables the function that sends a trap when the line card is FAULT alarm occurs. To enable
the function, use the ‘no’ command. The default value is ENABLED.
configure snmp trap linecard <shelf/slot> delete disable
This command disables the function that sends a trap when the line card is DELETED alarm occurs. To
enable the function, use the ‘no’ command. The default value is ENABLED.
configure snmp trap interface <slot>/<port> lh/sh bias disable
configure snmp trap interface <slot>/<port> lh/sh temp disable
configure snmp trap interface <slot>/<port> lh/sh absent disable
configure snmp trap interface <slot>/<port> lh/sh mismatch disable
configure snmp trap interface <slot>/<port> lh/sh los disable
These commands control traps related to interfaces. To enable these functions, use the ‘no’ command. The
default value is ENABLED.
【
Example
】
4.7
configure system
【
Format
】
configure system < >
configure system name <“string”>
This command sets the node (host) name of the OTS series. Place the host name between quotation marks
“ ” when setting it. This value is registered in the system group MIB system names. The default value is null.
The setting should be in ASCII characters and be 255 characters or less.
【
Example
】
*192.168.0.144:> configure snmp trap interface 2/1 lh bias disable
*192.168.0.144:> configure snmp trap interface 2/1 lh mismatch disable
*192.168.0.144:> configure snmp trap interface 2/1 lh los disable
192.168.0.244:> configure system
name system name
contact system contact
location system location
description system description