Fiber Patch Cord Connecter
- Remove the fiber connector dust cap and wipe the connector. Use a microscope (100X
or 200X) to check the end of the connector for scratches or debris.
- If there are no scratches or debris, the connector is clean and ready for use. If scratches
or debris are found, repeat the fiber patch cord connector cleaning procedure.
Fiber optic connector on the rear panel of the transmitter
- The connector can be cleaned with compressed air cleaning connecter due to the
protection of plastic sleeve. Compressed air should meet the following requirements:
- Use inert gas to achieve complete dust removal.
- High precision filtration to achieve < 0.2 microns.
- Recommended for use in optical systems.
- Using compressed air that meets the above requirements. Uncover the dust cover
of the plastic sleeve so that the nozzle of the compressed air container is approximately 6
feet away from the connector. Spray several times against the plastic sleeve so that the
connector should be clean and ready for use.
- If there is no compressed air, the transmitter's fiber optic connector can be cleaned
with a 2.5mm cotton swab, or the connector gasket can be removed to directly clean the
fiber optic connector inside.
- To remove the connector gasket, unscrew the screws on the left and right sides of the
gasket. Do not screw the bolt with plastic sleeve on the gasket.
- Slowly remove the connector pads from the rear panel of the transmitter and then
remove each fiber connector from the plastic sleeve.
- Clean each connector by the method of cleaning the fiber patch cord connector.
2. Verify that the laser button switch on the front panel of the transmitter is in the off
position.
3. Use two fiber patch cord, one connected to the output of the transmitter and the
high-power fiber amplifier, and the other connected to the output of the High Power Optical
Amplifier and an optical power meter.
.4 Use an optical power meter to ensure that the transmitter’s output optical power is within
the rated range.
5 Turn on the transmitter's laser button switch and then turn on the High Power Optical
Amplifier electronic switch.
Cautious: Handle the fiber carefully. When removing the fiber connector gasket,
do not operate the fiber beyond the tensile and bending radii defined in the specification.