OPTON PTA5102Y-16 Скачать руководство пользователя страница 3

 

Specifications   

Description 

Unit 

Value 

Conditions / Notes 

Optical Specifications

 

Fiber connector   

nm 

TVinput:1550nm 
Output:1550nm        SC/APC 

 

Input Power 

dBm 

-3~+10 1550nm 

  rec2~+10dBm 

Output Power 

dBm 

16*16,16*19,16*22 

@+6dBm Input 

Laser Bias current 

Pump 

16*16dBm 
3100mA±200mA 
@+6dBm input 

Alarm range: Out of   
1800mA~4600mA 

Laser Bias current 
 

Pump 

16*19dBm 
3300mA±200mA 
@+6dBm input 

Alarm range: Out of   
1500mA~4800mA   

Laser Bias current 

Pump 

16*22dBm 
3100mA±200mA 
@6dBm input 

Alarm range: Out of   
1800mA~4600mA 

Output 

Power 

Stability 

dB

 

0.1 

@+6dBm Input 

Noise Figure 

dB 

4(max 5) 

@+6dBm Input 

Isolation 
(Input/Output) 

dB 

30 

 

Return 

Loss 

(Input/Output) 

dB 

55 

 

Polarization 
Dependent Gain 

dB 

max 0.5 

 

Polarization 

Mode 

Dispersion 

ps 

max 0.5 

 

Electrical Specifications

 

Communication 
Interface 

 

RJ45, RS-232 

9600bps 

Input voltage 

VAC 

1pc 220V 

1PC -12 V DC 

Consumption 

15 maximum 

 

Fuse 

2   

 

Connector 

IEC 

Male power connector 

 

Environmental Specifications

 

Operating 
Temperature 

 

-5 ~55 

 

Storage Temperature 

 

-25 ~70 

 

Storage Humidity 

RH% 

≤95 

No Condensation 

Содержание PTA5102Y-16

Страница 1: ... also provide monitors and associated alarms for all vital characteristics The status and management of the device can be monitored and managed either from the LCD front panel display Web or remotely via Ethernet based SNMP The device also support multipul optical output by build in PLC splitter and FWDM 1310nm 1490nm optical multiplexer for Triple play FTTX network applications Feature Standard 1...

Страница 2: ...www netlinkict com Diagram ...

Страница 3: ...A Laser Bias current Pump 16 22dBm 3100mA 200mA 6dBm input Alarm range Out of 1800mA 4600mA Output Power Stability dB 0 1 6dBm Input Noise Figure dB 4 max 5 6dBm Input Isolation Input Output dB 30 Return Loss Input Output dB 55 Polarization Dependent Gain dB max 0 5 Polarization Mode Dispersion ps max 0 5 Electrical Specifications Communication Interface RJ45 RS 232 9600bps Input voltage VAC 1pc 2...

Страница 4: ...y s maximum power 1550nmEDFA can work in the temperature range of 0 C 50 C An ambient temperature of 25 C and humidity which is no more than 95 non condensing conditions is recommended If necessary the equipment should maintain proper temperature and humidity within these limits It is recommended that this equipment be operated in a low dust environment 3 The device can be powered by AC or regulat...

Страница 5: ...the transmitter s fiber optic connector can be cleaned with a 2 5mm cotton swab or the connector gasket can be removed to directly clean the fiber optic connector inside To remove the connector gasket unscrew the screws on the left and right sides of the gasket Do not screw the bolt with plastic sleeve on the gasket Slowly remove the connector pads from the rear panel of the transmitter and then r...

Страница 6: ...o switch the menu to the laser switch status menu That is the first line of the menu displays Laser Key State and the second line displays the position of OFF Press the Enter button and then press the ESC button At this time the second line on the front panel displays Set OFF Then press the up key or the Down key to set the switch to the open state Set ON Finally press the ESC key to save and exit...

Страница 7: ...State Laser Key State Menu 7 Pin Input Optical Power Menu 8 Pout Output Optical Power Menu 9 LD BIAS Pump1 Bias Current Menu 10 COOL CUR Pump1 Cooling Current Menu 11 LD TEMP Pump1 Temperature Menu 12 LD BIAS Pump2 Bias Current Menu 13 Power_1 5V Power Supply 1 Voltage Menu 14 Power_2 5V Power Supply 2 Voltage Menu 15 Temperature in Box Machine Temperature Menu 16 IP ADDR ...

Страница 8: ...ntinue to operate when it issues a warning the warning can be eliminated by continuous self test of the equipment or restoration of the relevant system parameters to the normal range Some serious alarms can be eliminated by turning the power off and on again If the relevant parameters return to the normal range the alarm will automatically disappear Most of the warnings are triggered when the erro...

Страница 9: ...prevent many potential problems by paying attention to the following information 1 Place the PUMP laser in an operating range where the ambient temperature is between 0 C and 50 C and other conditions meet the requirements It is recommended to place the Optical Amplifier in a low dust environment 2 Ensure that the rear panel fan and front panel socket holes are clear and the rear panel fan is runn...

Страница 10: ... Connect the optical fibers of all ports before power on The optical connector cannot be plugged or unplugged while the machine is working The machine cannot move or shake while working ...

Отзывы: