English 83
ADDITIONAL INFORMATION
SEND to projector
232 ASCII
Code
HEX Code
Function
Description
~XX109 1
7E 30 30 31 30 39 20 31 0D Lamp Reminder
On
~XX109 0
7E 30 30 31 30 39 20 30 0D
Off (0/2 for backward compatible)
~XX110 1
7E 30 30 31 31 30 20 31 0D Lamp Mode
Bright
~XX110 2
7E 30 30 31 31 30 20 32 0D
Eco
~XX110 5
7E 30 30 31 31 30 20 35 0D
Power
~XX326 0
7E 30 30 33 32 36 20 30 0D Power /100%
~XX326 1
7E 30 30 33 32 36 20 31 0D Power /95%
~XX326 2
7E 30 30 33 32 36 20 32 0D Power /90%
~XX326 3
7E 30 30 33 32 36 20 33 0D Power /85%
~XX326 4
7E 30 30 33 32 36 20 34 0D Power /80%
~XX111 1
7E 30 30 31 31 31 20 31 0D Lamp Reset
Yes
~XX320 1
7E 30 30 33 32 30 20 31 0D Optional Filter Installed
Yes
~XX320 0
7E 30 30 33 32 30 20 30 0D
No (0/2 for backward compatible)
~XX322 0
7E 30 30 33 32 32 20 30 0D Filter Reminder
Off
~XX322 1
7E 30 30 33 32 32 20 31 0D
300 hrs
~XX322 2
7E 30 30 33 32 32 20 32 0D
500 hrs
~XX322 3
7E 30 30 33 32 32 20 33 0D
800 hrs
~XX322 4
7E 30 30 33 32 32 20 34 0D
1000 hrs
~XX323 1
7E 30 30 33 32 33 20 31 0D Filter Reset
Yes
~XX313 1
7E 30 30 33 31 33 20 31 0D Information menu
On
~XX313 0
7E 30 30 33 31 33 20 30 0D
Off(0/2 for backward compatible)
~XX112 1
7E 30 30 31 31 32 20 31 0D Reset
Yes
~XX210 n
7E 30 30 32 30 30 20 n 0D
Display message on the OSD n: 1-30 characters
SEND to emulate Remote
~XX140 10 7E 30 30 31 34 30 20 31 30 0D
Up
~XX140 11 7E 30 30 31 34 30 20 31 31 0D
Left
~XX140 12 7E 30 30 31 34 30 20 31 32 0D
Enter (for projection MENU)
~XX140 13 7E 30 30 31 34 30 20 31 33 0D
Right
~XX140 14 7E 30 30 31 34 30 20 31 34 0D
Down
~XX140 15 7E 30 30 31 34 30 20 31 35 0D
V Ke
~XX140 16 7E 30 30 31 34 30 20 31 36 0D
V Keystone -
~XX140 17 7E 30 30 31 34 30 20 31 37 0D
Volume -
~XX140 18 7E 30 30 31 34 30 20 31 38 0D
~XX140 20 7E 30 30 31 34 30 20 32 30 0D
Menu
~XX140 47 7E 30 30 31 34 30 20 34 37 0D
Source
SEND from projector automatically
232 ASCII
Code
HEX Code
Function
Projector Return Description
when Standby/Warming/Cooling/Out of
Range/Lamp fail/Fan Lock/Over
Temperature/ Lamp Hours Running Out/
Cover Open
INFOn
n=0 Standby
n=1 Warming
n=2 Cooling
n=3 Out of Range
n=4 Lamp fail
n=6 Fan Lock/
n=7 Over Temperature
n=8 Lamp Hours Running Out
READ from projector
232 ASCII
Code
HEX Code
Function
Projector Return Description
~XX121 1
7E 30 30 31 32 31 20 31 0D Input Source Commands
Okn
n = 0 None
n = 7 HDMI1
n = 8 HDMI2
n = 15 Displayport
n = 2 VGA1
n = 3 VGA2
n = 5 Video
n = 4 S-Video
n = 16 HDbaseT