Open the GUI and Load the XML configuration file 

Open a browser and type 192.168.1.200 in the address bar. Now you are in the “Operation” web 

page of the MTDV GUI.  

 

Figure 3: MTDV GUI – Operation tab 

Click the button “Import/Export XML” (top-right of the web page) and click “Browse XML file” to 

select and load the XML file previously downloaded. If you use a multichannel device (i.e. 

MTDV2CH-22A2, MTDV3CH-22A3, MTDV4CH-22A4) you can choose which channel to associate to 

the zoom (see Figure 4). 

The MTDV has 100 memory slots (from 0 to 99) to save motor positions. The XML file contains the 

information of the 4 motor positions for the 4 different magnification of the lens. You can specify 

the memory offset to save this information. For example, if you choose “0” motor positions are 

saved into 0, 1, 2, and 3 memory slots. If you choose “21” motor positions are saved into 21, 22, 23, 

and 24 memory slots.  Click “Import XML” and your MTDV is configured for your TCZRS family 

zoom lens. Please refresh the page to see the updated MTDV configuration. 

5.1.4.

 

Connect the TCZRS zoom lens 

Switch off your MTDV1CH-22A2 motion controller by disconnecting the power connector. Connect 

the TCZRS zoom lens using CBMT002 cable and power on the controller. 

Wait a few seconds, then open a browser and type 192.168.1.200 in the address bar. Now you are 

in the “Operation” web page of the MTDV GUI. At the bottom of the page there is a text box 

named “Memory slot (0-99)”. Type in that box a number in the range you choose while importing 

XML information (for example 0 ÷ 3 or 21 ÷ 24) and click “Load” button to load each position of 

the TCZRS zoom lens. 

Содержание TCZR036S

Страница 1: ...V 1 1 eng 8x Bi Telecentric zoom lenses with motorized control TCZR036S TCZR072S OPTICS INSTRUCTION MANUAL...

Страница 2: ...CIFICATIONS 4 4 1 Specifications table 4 4 2 Connector 5 5 INSTRUCTIONS FOR USE WITH MTDV MOTION CONTROLLER 6 5 1 First use of TCZRS with MTDV motion controller 6 5 2 Clamping turning on and focusing...

Страница 3: ...ver might be permanently damaged if deployed in the presence of strong vibrations and impulsive forces TCZRS must be properly clamped before usage Zoom Revolver must be mechanically constrained by ade...

Страница 4: ...04 0 8 40 2 000 11 0 08 0 2 35 TCZR072S 0 125 11 157 8 16 0 05 0 1 53 0 35 C Yes 279 7 144 103 2850 0 250 11 0 08 13 2 40 0 500 11 0 05 3 3 40 1 000 11 0 07 0 8 35 Notes 1 Working F the real F of a l...

Страница 5: ...ibration sources and impulse forces 4 2 Connector Figure 1 DB15 HD connector male panel view PIN NAME DESCRIPTION 1 5V 5V encoder power supply 2 GND 0V encoder reference ground 3 ENC_A Encoder quadrat...

Страница 6: ...file Download the XML configuration file of your zoom lens on the web page https www opto e com configuration_files by typing the serial number of the lens and the Opto Security Number and by clickin...

Страница 7: ...set to save this information For example if you choose 0 motor positions are saved into 0 1 2 and 3 memory slots If you choose 21 motor positions are saved into 21 22 23 and 24 memory slots Click Impo...

Страница 8: ...rms a homing procedure and it stops to the last reached position After clamping attaching the camera and turning on the device please follow step by step the focusing procedure explained below 1 Adjus...

Страница 9: ...fication the distribution of reference point positions C1 C2 Cn has a mean Cm Xm Ym that is the Center of the repeatability area The radius of this area is the maximum distance between the mean of the...

Страница 10: ...V 1 1 eng 10...

Отзывы: