12
Port Name Cable
Color
Name
Note
Grey
ALARM_IN2
Alarm input port 2. It is to receive the on-off signal
from the external alarm source.
White
ALARM_NO
Alarm output port. It is to output the alarm signal
to the alarm device.
NO: normal open alarm output port.
It works with the ALARM_COM port.
Blue
RESET
It is to restore factory default setup.
When the device is working properly, please
connect the blue cable (restore default setup port)
to the orange cable (GND signal) for 5 seconds,
the device can resume factory default setup.
Orange
GND
Ground port
2.2
Framework and Dimension
Please refer to the following two figures for dimension information. The unit is mm. See Figure 2-2 and
Figure 2-2