UP-67M4, UP-127M4, 
UP-247M2, UP-487 

 

Modular amplifiers. v 2.3 

Modular 

amplifiers 

10 

(14)  DIP SWITCHES 

 

SHIELD - GND LINK (DIP 
switches number 1, 2, 3 & 4) 

These  4  DIP  switches  allow 
removing  the  cable  shielding 
from  the  internal  ground  of  the 
equipment  for  each  one  of  the 
RJ-45 connectors. Normally they 
are in ON position (shielding and 
ground  joined).  To  separate  the 
same,  place  the  corresponding 
DIP switch in OFF position. 

PRI-PRO LINK (DIP switches 
number 5 & 6) 

These  two  DIP  switches  join 
internally the H audio signal and 
the  C  audio  signal  (when  the 
input is balanced) that are in the 
PRIORITY  OUTPUT  with  the 
PROGRAM  INPUT. Normally they 
are  in  OFF  position  (separated 
audio signals). To join the same, 
place  the  corresponding  DIP 
switch in ON position. 

PRIORITY CONTROL IN (DIP 
switch number 7) 

In  OFF  position,  it  disables  the 
priority  contact  of  the  RJ45  PRIORITY  INPUT 
connector in its amplifier, but the RJ45 PRIORITY 
OUTPUT is still active. 

PRIORITY CONTROL OUT (DIP switch 
number 8) 

In OFF position, it disables the priority contact of 
the RJ45 PRIORITY OUTPUT connector. 

PRIORITY CONTACT SURVEILLANCE (DIP 
switch number 9) 

When in ON, enables the priority contact 
surveillance. It is necessary that the activator 
follows the figure 12A (if the priority is activated 
by means of RJ45 PRIORITY INPUT) or 12B (if 
the priority is activated by means of PRIORITY 
CTRL terminal block). When the surveillance 
detects short-circuit or 
open circuit in the priority 
control contact the contact 
number 2 of the 
SURVEILLANCE connector 
is activated. 

PROGRAM AUDIO BUS (DIP switch num. 10) 

In  ON  position,  Links  the  audio  input  from  one 
stage  with  the  audio  output  from  the  previous 
stage.  Allows  cascade  connection  between 
different power stages (see figure 9). 

PRIORITY AUDIO BUS (DIP switch num. 11) 

In  ON  position,  Links  the  audio  input  from  one 
stage  with  the  audio  output  from  the  previous 
stage.  Allows  cascade  connection  between 
different power stages (see figure 9). 

JPA (DIP switch num. 12) 

Set  on  ON  position  when  the  unit  includes  
OSC-02  oscillator  circuits  (installations  with 
DALA-01/0B). 
This  way,  when  the  power  unit  protection  is 
activated, the oscillation is stopped. 

 

Figure 11 

 

Figure 12A 

Figure 12B 

Содержание UP-127M4

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...Modular amplifiers v 2 3 Modular amplifiers 4 Contents 1 INTRODUCTION 5 2 FRONT VIEW 5 3 REAR VIEW 6 4 ATTENUATORS CONNECTION 11 5 ONE SECTION BLOCK DIAGRAM 12 6 TECHNICAL SPECIFICATIONS 13 7 DOCUMENT VERSION TRACKING 13 8 GUARANTEE 14 ...

Страница 5: ... the power delivered to the line The LED marked as 0 dB indicated the maximum power given by the amplifier 2 PROTECTION INDICATORS They light when the Protection is operating due either to an over loading or to a short circuit in the loudspeakers line 3 PRIORITY INDICATORS They light when the Priority channel is selected it is when the pin number 6 is joined to the pin number 8 in the RJ45 connect...

Страница 6: ...g with the 70 and 100V lines it should be remembered that The loudspeakers to be connected must have a line transformer The total connected power will be the sum of the power absorbed by the loudspeakers and this must be between 50 below and 20 above the rated power of the amplifier The power absorbed by a loudspeaker with a transformer is indicated on its terminals This power is on the 100 V line...

Страница 7: ...he junction must be made by means of external connections as shown in figure 5 The DIP switches 1 2 3 4 SHIELD GND LINK must be OFF and the external connection must be as shown in figure 6 pin 2 must be disconnected 6 GROUND CONTACT In all P A installations it is very important to have only a joining point between the signal ground and the mains ground contact If the P A installation is made up of...

Страница 8: ... line properly connected to the amplifier Note In installations with surveillance through DALA 01 0B set the JPA DIP switch to ON 10 SURVEILLANCE CONNECTION These connectors are used in installations with surveillance through SU 114N Connect the SU 114N to the power unit following the diagram shown in figure 7 11 PRIORITY CONTROL TERMINAL BLOCK These contacts allow the activation of the amplifier ...

Страница 9: ...in number 3 provides a 24 V d c voltage which can be used to supply devices of low consumption The maximum intensity supplied is of 200 mA in each channel In the PRIORITY channel when joining the pin number 6 to the pin number 8 the priority system is activated as well as the security paging auxiliary relay DIP switch 7 Pri ctrl in must be ON It is possible to transmit the priority control to othe...

Страница 10: ...ition it disables the priority contact of the RJ45 PRIORITY OUTPUT connector PRIORITY CONTACT SURVEILLANCE DIP switch number 9 When in ON enables the priority contact surveillance It is necessary that the activator follows the figure 12A if the priority is activated by means of RJ45 PRIORITY INPUT or 12B if the priority is activated by means of PRIORITY CTRL terminal block When the surveillance de...

Страница 11: ...e Priority contact is supervised or not When ON means surveillance activated DIP switch number 9 PRIORITY CONTACT SURVEILLANCE must be ON 4 ATTENUATORS CONNECTION Figure 13 INSTALLATION WITHOUT SURETY PAGING SEGURIDAD DE AVISOS Figure 14 6 CHANNELS WITH PRIORITY AND SURETY PAGING Figure 15 1 CHANNEL WITH PRIORITY AND SURETY PAGING ...

Страница 12: ...UP 67M4 UP 127M4 UP 247M2 UP 487 Modular amplifiers v 2 3 Modular amplifiers 12 5 ONE SECTION BLOCK DIAGRAM ...

Страница 13: ...ion Continuous ventilation with variation according to the temperature speed Dimensions mm 482 x 360 x 133 mm Rack units 3 units Weight 23 4 kg 24 3 kg 25 3 kg 20 kg Finishing Front panel in anodised black aluminium Cover in black enamelled steel 7 DOCUMENT VERSION TRACKING Reference system Type of Document Confidentiality N A Analogue systems Installation and operation guide Rev Date Modification...

Страница 14: ... the equipment including lack of maintenance 5 The guarantee shall not be valid whenever the following is observed Amendments or corrections made to the details of the guarantee certificate or purchase invoice Failure to produce the original invoice or the absence of a date on this Absence of the serial or batch number on the equipment 6 In the case of personal computers the guarantee will not cov...

Отзывы: