OPTIMUM
M A S C H I N E N - G E R M A N Y
Safety
Version 1.0 dated 2015-05-27
Page 12
Original operating instructions
F3
GB
before taking the machine in operation
- have read and understood the operating manual,
- be familiar with all safety devices and instructions.
Additional
requirements
regarding the
qualification
For work on the following CNC- machine parts there are additional requirements:
Electric components or operating materials: Must only be worked on by a qualified electri-
cian or person working under the instructions and supervision of a qualified electrician.
1.8
Operator positions
The operator position is in front of the CNC machine at the sight window or on the machine con-
trol panel.
1.9
Safety devices
Use the CNC machine only with properly functioning safety devices.
Stop the CNC machine immediately if safety device fails or is not functioning for any reason.
It is your responsibility!
If a safety device has been activated or has failed, the drilling machine must only be used if you
the cause of the fault has been eliminated,
you have verified that there is no danger to personnel or objects.
WARNING!
If you bypass, remove or deactivate a safety device in any other way, you are
endangering yourself and other personnel working with the CNC machine. The possible
consequences are:
injuries due to tools, workpieces or fragments hereof which are flying off at high
speed,
contact with rotating or moving parts,
fatal electrocution,
pulling-in of clothes.
The CNC machine includes the following safety devices:
a lockable main switch,
One EMERGENCY STOP push-button on the machine control panel and on the electronic
handwheel,
A locked, separating protective equipment around the CNC milling machine with sight win-
dows made of break-proof Makrolon.
Locking switch on the separating safety devices.
1.9.1 Lockable main switch
In the "0" position, the lockable main switch can be secured against accidental or non-author-
ised switching on by means of a padlock.
The power supply is interrupted by switchingoff the main plug.
Except for the areas marked by the pictogram in the margin. In these areas there might be volt-
age, even if the main switch is switched-off.