OPTIMUM
M A S C H I N E N - G E R M A N Y
Operation
Version 1.0.1 dated 2016-04-25
Page 20
Original operating instructions
DX13V | DX15V
GB
4.4.1
Drilling
Switch on the master switch.
Insert and tighten the drill bit.
Clamp the workpiece.
Unlock the emergency-stop.
Close drill chuck protection.
Push Start.
If necessary, change the preset speed with the rotary knob.
Press Stop.
INFORMATION
For a long-term standstill of the machine switch it off at the main switch.
4.4.2 Removing the Drill Chuck from the Spindle Holding Fixture
DX13V
A friction-locking connector holds and centres the drill chuck in the B16 holding fixture.
Rotate the nut downwards; the drill chuck is pushed out of the chuck cone. If necessary,
exert counter pressure on the drill chuck.
INFORMATION
If the nut is no longer available, you can use, for example, an aluminium wedge or other
appropriate lever to remove the drill chuck from the spindle holding fixture.
Img.4-2:
Nut for loosening the connection DX13V
The drill chuck and the taper mandrel are loosened from the drill spindle by means of a drill
drift.
WARNING!
Only disassemble the drill chuck if the drilling machine is disconnected from the
electrical supply.
Nut
Содержание OPTi drill DX 13V