![Optimum HNC-2012 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/optimum/hnc-2012/hnc-2012_operating-instructions-manual_1642919011.webp)
11
ASSEMBLY
• Remove the packing and make sure that the appliance is
intact.
• Place the appliance upside down.
• Fix the feet with screws. After assembling, make it
upstanding.
OPERATION OF THE DEVICE
When connecting the device and during maintenance and
operation of the device adhere strictly to the safety rules
described in this manual, in the “Principles of safe operation”
section. Place the convection heater in a proper place
(in accordance with the safety rules). Make sure that all mode
switches are set to the “0” position and that the thermostat
knob is set to “min.” position. Plug the heater’s cord to the
power source. Set the mode switch to the desired mode of
operation:
2 buttons for setting heat in 1 of 3 ranges:
“I” - 750 W
“II” - 1,250 W
“I”+ “II” – 2,000 W (750+1,250)
Then turn the thermostat knob towards max. position, which
will make the heater start (if the thermostat knob remains
at “min.” position, the convection heater will not start
operating). With the thermostat knob you can adjust the
automatic operation of the convection heater - by setting
a specific level of the room temperature. At the moment
the room temperature reaches the set level (set on the
thermostat), the device will turn off; if the temperature in
the room drops below the set level, the convection heater
will turn on again. Additionally the convection heater has
an internal fan (switched by a separate button) to assist in
spreading hot air - turbo function.
Automatic power-off protection
If overheating, it will power off automatically, protect the
heater, use safely.
CLEANING AND MAINTENANCE
The convection heater should be kept clean. Before cleaning
or any other maintenance work it is essential to disconnect
the device from the power source (in accordance with the
safety rules, including unplugging the device) and wait
until the heater cools down. Use only a soft, damp cloth for
cleaning. Do not use abrasive cloths or sponges, as they can
scratch the surface. Never use detergents or other chemicals
to clean the device. Do not allow electrical parts (including
switches, plugs, heating elements) to come into contact with
water.
Take proper care of the equipment to maintain the warranty.
TECHNICAL DATA
Operating voltage: 230 V~
Power output: 750/1250/2000 W
Frequency: 50 Hz
Noise level: < 60 dB
Warm-up Time: 5s
Room size used: <20 m²
Ecology – Environmental Protection
The “crossed-out trash bin” symbol on electrical
equipment or packaging indicates that the device
cannot be treated as general household waste and
should not be disposed of into containers for such waste.
Obsolete or broken-down electrical device
should be
delivered to special designated collection points, organized
by local public administration, whose purpose is to collect
recyclable electrical equipment.
This way, each household helps reduce possible negative
effects influencing natural environment and allows the
reclaiming of materials which the product is made of.
Weight: 4,5kg
e
750 W
2000 W
1250 W
Turbo ventilation
ON/OFF
Heating
Convection heater with Turbo ventilation
Max.
temperature
Min. temperature
Thermostat knob
Содержание HNC-2012
Страница 4: ...4...
Страница 5: ...5...
Страница 6: ...6...
Страница 15: ...15 HNC 2012 89 336 E C 73 23 60 C RU...
Страница 16: ...16 1 2 3 4 5 6 7 8 2 I II 750 1250 2000 I II 750 1250 2000 O 50 750 W 2000 W 1250 W...
Страница 22: ...22 HNC 2012 89 336 73 23 CE 600 e 1 2 3 4 5 6 7 8 BG...
Страница 23: ...23 e 2 I II 750 W 125 W 2000 W I II 750 W 125 W 2000 W 50 750 W 2000 W 1250 W...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27 89 336 EEC 73 23 EWG CE 60 C i i 1 2 3 4 5 6 7 8 HNC 2012 UA...
Страница 28: ...28 e 2 I II 750W 1250W 2000W I II 750W 1250W 2000W O i 50 750 W 2000 W 1250 W...