![Optimum CNC Controller III Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/optimum/cnc-controller-iii/cnc-controller-iii_operating-manual_1642804007.webp)
OPTIMUM
M A S C H I N E N - G E R M A N Y
Description of the connection
29 / 11 / 2006
Page
7
Description of the connection CNC Controller III and VI ; Version 2.0.1
©
2006
GB
6.1.3
Assignment of signals at the parallel port 1, CNC controller VI (port / PC)
The following assignment of signals is required at the parallel port 1.
6.1.4
Assignment of signals at the parallel port 2, CNC controller VI (port / PC)
The following assignment of signals is required at the parallel port 2.
Pin No
Application
Description
DB 25 male
1
Relay 9
Switching output e.g. motor on
2
Direction X-axis
Direction signal to control the axis
3
Cycle X
Cycle signal to control the step motor
4
Direction Y
Direction signal to control the axis
5
Cycle Y
Cycle signal to control the step motor
6
Direction Z
Direction signal to control the axis
7
Cycle Z
Cycle signal to control the step motor
8
Direction 4th axis
Direction signal of the optional 4th axis
“Optional 4th axis on parallel port 1“ on page 8
9
Cycle 4th axis
Cycle signal of the optional 4th axis
nal 4th axis on parallel port 1“ on page 8
10
Free
Not assigned
11
Reference switch Z
axis
“Assignment of signals at the port refe-
rence switch (Ref.switch)“ on page 6
12
Reference switch Y
axis
13
Reference switch X
axis
14
Relay 10
Switching output e.g. coolant on
15
Reference switch 4th
axis
16 - 24
Free
Not assigned
25
OV DC, earthing
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1
Pin No
Application
Description
DB 25 male
1
Relay 11
Switching output e.g. motor on
2
Direction X - axis
Direction signal to control the axis
3
Cycle X
Cycle signal to control the step motor
4
Direction Y
Direction signal to control the axis
5
Cycle Y
Cycle signal to control the step motor
6
Direction Z
Direction signal to control the axis
7
Cycle Z
Cycle signal to control the step motor
8 - 10
Free
Not assigned
11
Reference switch Z
axis
“Assignment of signals at the port refe-
rence switch (Ref.switch)“ on page 6
12
Reference switch Y
axis
13
Reference switch X
axis
14
Relais 12
Switching output e.g. coolant on
15 - 24
Free
Not assigned
25
OV DC, earthing
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
1